首页 | 本学科首页   官方微博 | 高级检索  
     


The relationship between the photoplethysmographic waveform and systemic vascular resistance
Authors:Aymen A. Awad  Ala S. Haddadin  Hossam Tantawy  Tarek M. Badr  Robert G. Stout  David G. Silverman  Kirk H. Shelley
Affiliation:(1) Department of Anesthesiology, Yale University School of Medicine, 333 Cedar Street, P.O. Box 208051, New Haven, CT 06520-8051, USA;(2) Department of Anesthesia, Benha Faculty of Medicine, Zagazig University, Zagazig, Egypt
Abstract:Objective The objective of this study was to determine the relationship between systemic vascular resistance (SVR), finger & ear photoplethysmographic measurements in 14 adult patients undergoing coronary artery bypass grafting (CABG). Methods Patients were monitored with photoplethysmographs of the finger and ear and continuous cardiac output (QT) via thermodilution catheter. The relationship between SVR, finger plethysmographic amplitude, width and ear plethysmographic amplitude, width was assessed with linear regression. Results The finger plethysmographic amplitude had a low correlation r value = −0.15, while finger plethysmographic width had a better correlation r value = 0.56. The correlation between SVR and ear plethysmographic amplitude and width were −0.24 and 0.62 respectively. Using receiver operating characteristic analysis the ear plethysmographic width had both better sensitivity and specificity than the finger plethysmographic width in identifying high and low SVR. Using a multiple regression analysis, SVR was estimated from the pulse oximeter waveforms: SVR calculated = 27.27 + (3978.53 × Ear pulse oximeter width) − (8.91 × Ear pulse oximeter area) + (1986.3 × Finger pulse oximeter width). Bland–Altman analysis was used the bias was 29.8 dynes s cm−5, standard deviation was 587.3, upper and lower limit of agreement were 1204.45, and −1144.8 dynes s cm−5 respectively. Conclusion The data indicate that pulse width of finger and ear plethysmographic tracing are more sensitive to changes in SVR than the other indices. An appreciation of changes in pulse width may provide valuable evidence with respect to changes in peripheral vascular tone. Awad AA, Haddadin AS, Tantawy H, Badr TM, Stout RG, Silverman DG, Shelley KH. The relationship between the photoplethysmographic waveform and systemic vascular resistance.
Keywords:photoplethysmograph  vascular resistance  non-invasive monitoring
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号