Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary angiography
Authors:Filippo Cademartiri  Ludovico La Grutta  Giuseppe Runza  Alessandro Palumbo  Erica Maffei  Nico RA Mollet  Tommaso Vincenzo Bartolotta  Pamela Somers  Michiel Knaapen  Stefan Verheye  Massimo Midiri  Ronald Hamers  Nico Bruining
Institution:(1) Department of Radiology, Erasmus Medical Center, Dr. Molenwaterplein, 40, 3015GD Rotterdam, The Netherlands;(2) Department of Cardiology, Erasmus Medical Center, Rotterdam, The Netherlands;(3) Department of Radiology, Azienda Ospedaliero-Universitaria, Parma, Italy;(4) Department of Cardiology, Azienda Ospedaliero-Universitaria, Parma, Italy;(5) Department of Radiology, DIBIMEL, University of Palermo, Palermo, Italy;(6) Department of Pathology, Middelheim Hospital, Antwerp, Belgium;(7) Department of Cardiology, Middelheim Hospital, Antwerp, Belgium
Abstract:Attenuation variability (measured in Hounsfield Units, HU) of human coronary plaques using multislice computed tomography (MSCT) was evaluated in an ex vivo model with increasing convolution kernels. MSCT was performed in seven ex vivo left coronary arteries sunk into oil followingthe instillation of saline (1/∞) and a 1/50 solution of contrast material (400 mgI/ml iomeprol). Scan parameters were: slices/collimation, 16/0.75 mm; rotation time, 375 ms. Four convolution kernels were used: b30f-smooth, b36f-medium smooth, b46f-medium and b60f-sharp. An experienced radiologist scored for the presence of plaques and measured the attenuation in lumen, calcified and noncalcified plaques and the surrounding oil. The results were compared by the ANOVA test and correlated with Pearson’s test. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The mean attenuation values were significantly different between the four filters (p < 0.0001) in each structure with both solutions. After clustering for the filter, all of the noncalcified plaque values (20.8 ± 39.1, 14.2 ± 35.8, 14.0 ± 32.0, 3.2 ± 32.4 HU with saline; 74.7 ± 66.6, 68.2 ± 63.3, 66.3 ± 66.5, 48.5 ± 60.0 HU in contrast solution) were significantly different, with the exception of the pair b36f–b46f, for which a moderate-high correlation was generally found. Improved SNRs and CNRs were achieved by b30f and b46f. The use of different convolution filters significantly modifief the attenuation values, while sharper filtering increased the calcified plaque attenuation and reduced the noncalcified plaque attenuation.
Keywords:Multislice computed tomography  Coronary angiography  Coronary plaque  Convolutions kernels
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号