Departments of Surgery, Cardiology, and Pathology of the Hennepin County General Hospital, and the St. Louis Park Medical Center, Minneapolis, Minn
Abstract:
A safe method for replacement of the entire aortic valve, root, and ascending aorta for aortic insufficiency associated with an ascending aortic aneurysm is supported. This method utilizes a composite synthetic graft and valve with direct annular suture and implantation of the coronary arteries in the graft. The advantages of the technique include a shortened operation and freedom from postoperative hemorrhage, paraprosthetic leakage, and recurrent aneurysm formation.