首页 | 本学科首页   官方微博 | 高级检索  
     

国产机械可脱式弹簧圈介入治疗的动物试验及临床应用
引用本文:Zhang H,Ling F,Du J,Wang D,Zhang J,Miu Z,Ma D,Song Q,Hao M,Li X. 国产机械可脱式弹簧圈介入治疗的动物试验及临床应用[J]. 中华外科杂志, 1998, 36(7): 392-394,I079
作者姓名:Zhang H  Ling F  Du J  Wang D  Zhang J  Miu Z  Ma D  Song Q  Hao M  Li X
作者单位:[1]卫生部北京医院介入神经放射研究中心 [2]北京医院病理科
摘    要:目的 通过国产机械可脱式弹簧圈(MDS)的动物试验及临床初步应用,观察其操作性能及致血凝性。方法 利用中国白兔建立分叉部位动脉瘤模型,2周后进行国产机械可脱式弹簧圈的栓塞。5个动脉瘤共使用弹簧圈24枚。2 ̄3周后造影复查,并处死动物,滠出动脉瘤标本进行病理检查。临床应用于10例患者的栓塞,其中动脉瘤7例,外伤性颈内动脉海绵窦瘘(CCF)2例,海锦窦区硬脑膜动静脉瘘(DAVF)1例。共使用弹簧圈14

关 键 词:颅内动脉瘤 栓塞疗法 MDS 介入疗法 动物实验

Animal experiment and clinical application of self-made mechanically detachable coils
Zhang H,Ling F,Du J,Wang D,Zhang J,Miu Z,Ma D,Song Q,Hao M,Li X. Animal experiment and clinical application of self-made mechanically detachable coils[J]. Chinese Journal of Surgery, 1998, 36(7): 392-394,I079
Authors:Zhang H  Ling F  Du J  Wang D  Zhang J  Miu Z  Ma D  Song Q  Hao M  Li X
Affiliation:Research Center of Interventional Neurooradiology, Beijing Hospital, Beijing 100730.
Abstract:OBJECTIVE: To evaluate the practical and thrombogenetic characteristics of self-made mechanically detachable coils by the animal experiment and primary clinical application. METHOD: The bifurcation type of aneurysm model was established on rabbit and embolized with self-made mechanically detachable coils 2 weeks after surgery. 24 coils were used in 5 experimental aneurysms. Control angiography was performed and the rabbits were sacrificed 2 - 3 weeks after the embolization. The embolized aneurysm samples were examined by pathologist. Ten patients were treated with self-made mechanically detachable coils in primary clinical application. They were divided into aneurysms (7 patients), traumatic carotid-carvenous fistulas (2), dural arterio-venous fistula in carvenous sinus region (1). 146 coils were used totally and all were delivered with mechanical detachable system (MDS Balt co. France). RESULT: Pathologically, the cavities of rabbit aneurysm models were occluded by tungsten coils (2 complete, 3 almost complete). The coils were trapped in granulation tissue which was covered by a thin layer of endothelium on the surface facing the blood flow. In the coils dense packing ones, the aneurysms were completely excluded from the parent circulation by neointimal layers. In the practice procedures, the coils fit MDS (Balt co. France) very well and can be delivered, withdrew and detached smoothly. CONCLUSION: The self-made mechanically detachable coils have practical reliability and evident thrombogenetic effects.
Keywords:Cerebral aneurysm Embolization  therapeutic Radiography  interventional  
本文献已被 CNKI 维普 万方数据 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号