准分子激光原位角膜磨镶术后角膜后表面前突的影响因素
引用本文:张光明,张明昌,胡燕华,聂绍松.准分子激光原位角膜磨镶术后角膜后表面前突的影响因素[J].中华眼视光学与视觉科学杂志,2012,14(12):745-748.
作者姓名:张光明  张明昌  胡燕华  聂绍松
作者单位:ZHANG Guang-ming,ZHANG Ming-chang,HU Yan-hua,NIE Shao-song
摘    要:目的 描述准分子激光原位角膜磨镶术(LASIK)后角膜后表面前突并探讨影响其前突程度的因素.方法 前瞻性系列病例研究.2006年12月至2007年2月在华中科技大学同济医学院附属协和医院眼科行LASIK手术患者82例(通过3年的观察,无一例出现圆锥角膜),其中男38例,女44例,年龄18~44岁,平均(24.2±5.5)岁,取右眼数据进行分析.采用OrbscanⅡz、Goldman眼压计、超声角膜测厚仪分别测量这82眼手术前后角膜地形图、眼压以及角膜厚度.采用t检验和Pearson相关分析与线性回归等统计学方法.结果 ①LASIK术后角膜后表面最佳拟合球面半径缩短(113.32±66.87) μm,平均前突(71.97±28.70)μm,术前术后角膜后表面曲率差为(0.93±0.54)D.②LASIK手术后角膜后表面都有不同程度轻微前突,其程度与术前眼压呈正相关(r=0.461,P<0.01);与术后角膜瓣下残余基质厚度呈负相关(r=-0.453,P<0.01).③在36个月观察中,无一例发生角膜扩张,但术后角膜后表面都不同程度向前突出.结论 角膜后表面前突是LASIK术后角膜变薄的必然反应,其程度与术前眼压呈正相关,与术后角膜瓣下残余基质厚度呈负相关.

关 键 词:眼内压  角膜磨镶术  激光原位    角膜地形图  角膜后表面前突  屈光回退  
收稿时间:2011-11-04

Factors affecting the forward shift of the posterior corneal surface in laser in situ keratomileusis
ZHANG Guang-ming , ZHANG Ming-chang , HU Yan-hua , NIE Shao-song.Factors affecting the forward shift of the posterior corneal surface in laser in situ keratomileusis[J].Chinese Journal of Optometry Ophthalmology and Visual Science,2012,14(12):745-748.
Authors:ZHANG Guang-ming  ZHANG Ming-chang  HU Yan-hua  NIE Shao-song
Abstract:Objective To investigate the forward shift of the posterior corneal surface and related influential factors after laser in situ keratomileusis (LASIK).Methods It was a prospective case series study.Eighty-two patients with myopia (38 males and 44 females) who had undergone LASIK at Union Hospital between December 2006 and February 2007 were retrospectively reviewed.The average age was 24.2±5.5 years,ranging from 18 to 44 years.No case of keratoconus was found during 3 years of follow-up.Intraocular pressure,corneal thickness and topography measurements were obtained with a Goldmann tonometer,ultrasonic corneal pachymeter and Orbscan Ⅱ z before and after surgery.All surgery was performed by the same surgeon using a 217Z100 Bausch & Lomb.Results After LASIK,the best fit sphere radius of the posterior corneal surface was shortened by 113.32±66.87 μm,with an average forward shift of 71.97±28.70 μm.The difference in the posterior corneal surface power between pre-and post-operation was 0.93±0.54 D.The forward shift of the posterior corneal surface showed a positive correlation with preoperative intraocular pressure (r=0.461,P<0.01),and a negative correlation with residual stromal bed thickness (r=-0.453,P<0.00).There was a forward shift of varying degrees in the posterior comeal surface in most cases,including several severe cases.But no corneal ectasia was observed during the follow-up period of 36 months.Conclusion The forward shift of the posterior corneal surface could be an inevitable response because of corneal thinning after LASIK,and a change in the posterior corneal surface showed a positive correlation with preoperative intraocular pressure and a negative correlation with residual stromal bed thickness.
Keywords:Intraocular pressure  Keratomileusis  laser in situ  Corneal topography  Forward shift of posterior corneal surface  Refractive regression