首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of monoenergetic late iodine enhancement dual-energy computed tomography for imaging of chronic myocardial infarction
Authors:Julian L. Wichmann  Ruta Arbaciauskaite  J. Matthias Kerl  Claudia Frellesen  Boris Bodelle  Thomas Lehnert  Nadejda Monsefi  Thomas J. Vogl  Ralf W. Bauer
Affiliation:1. Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany
2. Department of Cardiology, Lithuanian University of Health Sciences, Kaunas, Lithuania
3. Department of Thoracic and Cardiovascular Surgery, University Hospital Frankfurt, Frankfurt, Germany
Abstract:

Objectives

To evaluate image quality and diagnostic accuracy of selective monoenergetic reconstructions of late iodine enhancement (LIE) dual-energy computed tomography (DECT) for imaging of chronic myocardial infarction (CMI).

Methods

Twenty patients with a history of coronary bypass surgery underwent cardiac LIE-DECT and late gadolinium enhancement (LGE) magnetic resonance imaging (MRI). LIE-DECT images were reconstructed as selective monoenergetic spectral images with photon energies of 40, 60, 80, and 100 keV and the standard linear blending setting (M_0.6). Images were assessed for late enhancement, transmural extent, signal characteristics and subjective image quality.

Results

Seventy-nine myocardial segments (23 %) showed LGE. LIE-DECT detected 76 lesions. Images obtained at 80 keV and M_0.6 showed a high signal-to-noise ratio (15.9; 15.1), contrast-to-noise ratio (4.2; 4.0) and sensitivity (94.9 %; 92.4 %) while specificity was identical (99.6 %). Differences between these series were not statistically significant. Transmural extent of LIE was overestimated in both series (80 keV: 40 %; M_0.6: 35 %) in comparison to MRI. However, observers preferred 80 keV in 13/20 cases (65 %, κ?=?0.634) over M_0.6 (4/20 cases) regarding subjective image quality.

Conclusions

Post-processing of LIE-DECT data with selective monoenergetic reconstructions at 80 keV significantly improves subjective image quality while objective image quality shows no significant difference compared to standard linear blending.

Key Points

? Late enhancement dual-energy CT allows for detection of chronic myocardial infarction. ? Monoenergetic reconstructions at 80 keV significantly improve subjective image quality. ? 80 keV and standard linear blending reconstructions show no significant differences. ? Extent of CMI detected with LIE-DECT is overestimated compared with MRI.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号