Dual energy CT of peripheral arteries: effect of automatic bone and plaque removal on image quality and grading of stenoses |
| |
Authors: | Meyer B C Werncke T Hopfenmüller W Raatschen H J Wolf K-J Albrecht T |
| |
Affiliation: | Charité-University Hospital, Campus Benjamin Franklin, Department of Radiology and Nuclear Medicine, Hindenburgdamm 30, 12200 Berlin, Germany. Bernhard.Meyer@charite.de |
| |
Abstract: | PurposeTo evaluate the effect of automatic bone and plaque removal on image quality and grading of steno-occlusive lesions in patients undergoing dual energy CT angiography (CTA) of lower extremity.Materials and methodsDual energy (DE) runoff CTA was performed in 50 patients using the following parameters: collimation 2 × 32 × 0.6; tube potentials, 80 kV and 140 kV; reconstructed slice thickness 1 mm. 100 mL iomeprol 400 and 50 mL saline were injected at 4 mL/s. Separate datasets were calculated for each of the two tubes and used to generate automatically bone-subtracted images (ABS) as well as bone and plaque subtracted images (ABPS). Residual bone in the ABS dataset was removed manually (=ABS-B dataset). In addition, a weighted average dataset from both dual energy acquisitions resembling a routine 120 kV CT acquisition was used for standard manual bone subtraction (MBS). Operator time for bone removal was measured. Effectiveness of bone subtraction and presence of vessel erosions was assessed by two readers in consensus. Stenosis grading in plaque subtracted and unsubtracted images was assessed and correlated.ResultsResidual bone fragments (ribs: 46%, patella: 25%, spine: 4%, pelvis: 2%, tibia 2% of patients) were only observed with ABS. The time needed to manually remove these residual bones was 2.1 ± 1.1 min and was significantly lower than the duration of manual bone removal (6.8 ± 2.0 min, p < 0.0001, paired t-test). A total of 1159 arteries were analyzed. Compromising vessel erosions were observed less frequently in the ABS-B dataset (10.6%) than in the MBS dataset (15.2%, p < 0.001, wilcoxon’s signed rank test). A total of 817 steno-occlusive lesions were assessed. While the agreement of grading of steno-occlusive lesions was good at the levels of the aorta and the pelvic arteries (κ = 0.70 in both, Cohen’s kappa statistics), it was moderate at the level of the thigh arteries (κ = 0.57) and poor at the level of the calf (κ = 0.16).ConclusionDE CTA has substantial advantages over conventional CTA. Automatic bone subtraction is more time efficient and reliable. Automatic plaque subtraction for the first time provides a true CTA-luminogram which is easy to interpret and reduces the need for further post-processing. DE CTA provides best results in arteries of the thigh; below the knee, plaque subtraction is less accurate. |
| |
Keywords: | Dual energy MDCT angiography Runoff CTA Peripheral arteries |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|