Experimental Investigation on the Static Performance of Stud Connectors in Steel-HSFRC Composite Beams |
| |
Authors: | Fangwen Wu Wenlong Tang Chengfeng Xue Guorui Sun Yanpeng Feng Hao Zhang |
| |
Affiliation: | 1.School of Highway, Chang’an University, Xi’an 710064, China; (F.W.); (W.T.); (Y.F.);2.School of Civil Engineering, Xijing University, Xi’an 710123, China;3.School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China;4.State Key Laboratory of Mechanical Behaviour and System Safety of Traffic Engineering Structures, Shijiazhuang Tiedao University, Shijiazhuang 050043, China |
| |
Abstract: | In this research, high strength fiber reinforced concrete (HSFRC) was used to replace the normal strength concrete (NSC) in steel-concrete composite beams to improve their working performance, which might change the static performance of stud connectors. Firstly, push-out tests were conducted to investigation on the static performance of stud connectors in steel-HSFRC composite beams and compared with steel-NSC composite beams. Studs of 8 sizes, 13 mm, 16 mm, 19 mm and 22 mm in diameter and 80 mm and 120 mm in height were adopted to study the influence of stud dimension. The test phenomenon shown that the crack resistance of HSFRC was better than that of NSC, and there were some splitting cracks on NSC slabs whereas no visible cracks on HSFRC slabs when specimens failed. Next, the load-slip curves of studs were analyzed and a typical load-slip curve was proposed which was divided into four stages. In addition, the effects of test parameters were analyzed according to the characteristic points of load-slip curve. Compared with NSC slab, HSFRC slab could provide greater restraining force to the studs, which improved the shear capacity and stiffness of studs while suppressed the ductility of studs. The shear capacity, stiffness and ductility of studs would significantly increase with the increasement of stud diameter and the studs with large diameter were more suitable for steel-HSFRC composite beams. The stud height had no obvious influence on the static performance of studs. Finally, based on the test results, the empirical formulas for load-slip curve and shear capacity of stud connectors embedded in HSFRC were developed which considered the influence factors more comprehensively and had better accuracy and applicability than previous formulas. |
| |
Keywords: | high strength fiber reinforced concrete (HSFRC) stud connector static performance push-out test stud dimension |
|
|