Delayed hypoxemia after bone cement insertion during total hip replacement under spinal anesthesia--a case report |
| |
Authors: | Hong Chian-Lang Liu Hung-Pin Wu Chung-Yuan Ho Angie C Y Shyr Ming-Hwang Wong Chung-Hang Chun Han See |
| |
Affiliation: | Department of Anesthesia, Chang Gung Memorial Hospital at Chia Yi, No. 6, Sec West, Chia Pu Road, Putz City, Chia Yi, Taiwan, R.O.C. |
| |
Abstract: | We report a case of delayed hypoxemia in an aged healthy male patient, which developed 2 hours after cementation of the prosthesis in total hip replacement (THR) under spinal anesthesia. The patient was doing well throughout the operation but unfortunately, progressive tachypnea was noted 1 h after he was transferred to the recovery room (i.e. 2 h after the application of bone cement into the femur). An hour further, distinct wheeze was heard bilaterally on auscultation, which signified bronchospasm. Arterial blood gases analysis revealed a low PaO2 of 71 mmHg and a decrease of oxygen saturation to 91% with supplement of fractional oxygen of 35%. Aerosolization of bronchodilator with terbutaline was administered and supplemental fractional oxygen was increased to 50%. Although wheezing soon subsided, tachypnea and desaturation persisted. He was then transferred to the surgical intensive care unit for further management. Ventilation-perfusion lung scan was performed, which was suggestive of multiple pulmonary embolism. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|