首页 | 本学科首页   官方微博 | 高级检索  
     


Severe postpartum disruption of the pelvic ring: report of two cases and review of the literature
Authors:Zhiyong Hou  John T Riehl  Wade R Smith  Kent A Strohecker  Patrick J Maloney
Affiliation:1. The Department of Orthopaedic Surgery, University of Colorado School of Medicine, Denver, Colorado, USA
2. Swedish Medical Center, Englewood, Colorado, USA
3. The Department of Orthopaedic Surgery, Denver Health Medical Center, University of Colorado School of Medicine, Denver, Colorado, USA
4. Bay Pines VA Health Care System, Bay Pines, Florida, USA
Abstract:

Background

Intra-articular hardware penetration can occur during osteosynthesis of ankle fractures, jeopardizing patients' outcomes. The intraoperative recognition of misplaced screws may be difficult due to the challenge of adequate interpretation of specific radiographic views. The present study was designed to investigate the diagnostic accuracy of standardized radiographic ankle views to determine the accuracy of diagnosis for intra-articular hardware placement of medial malleolar screws in a cadaveric model.

Methods

Nine preserved human cadaveric lower extremity specimens were used. Under direct visualization, two 4.0 mm cancellous screws were inserted into the medial malleolus. Each specimen was analyzed radiographically using antero-posterior (AP) and mortise views. The X-rays were randomly uploaded on a CD-ROM and included in a survey submitted to ten selected orthopaedic surgeons. The "Standards for Reporting of Diagnostic Accuracy" (STARD) questionnaire was used to determine the surgeons' perception of accuracy of screw placement in the medial malleolus. The selection of items was based on evidence whenever possible, therefore the "inconclusive" category was added. Inter and intraobserver variations were analyzed by kappa statistics to measure the amount of agreement.

Results

There was a poor level of agreement (kappa 0.4) both in the AP and in the mortise view among all the examiners. Associating the two x-rays, the agreement remained poor (kappa 0.4). In the cases in which there was a diagnosis of articular penetration, there was a poor agreement related to which of the screws was intra-articular. The number of "inconclusive" responses was low and constant, without a statistically significant difference between the subspecialists

Conclusion

The routine intraoperative radiographic imaging of the ankle is difficult to interpret and unreliable for detection of intra-articular hardware penetration. We therefore recommend to reposition medial malleolar screws intraoperatively if there is any doubt regarding inadequate screw placement.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏