首页 | 本学科首页   官方微博 | 高级检索  
检索        

128层螺旋CT冠状动脉成像与选择性冠状动脉造影诊断冠心病价值的比较
引用本文:陈步星,马凤云,温智勇,罗维,赵希哲,康枫,周全红,阮剑洪.128层螺旋CT冠状动脉成像与选择性冠状动脉造影诊断冠心病价值的比较[J].中华心血管病杂志,2008,36(3).
作者姓名:陈步星  马凤云  温智勇  罗维  赵希哲  康枫  周全红  阮剑洪
作者单位:1. 北京电力医院心内科,100073
2. 北京电力医院放射科,100073
摘    要:目的 评价128层螺旋CT(MSCT)冠状动脉成像诊断冠状动脉疾病的价值.方法 对临床怀疑或确诊冠心病的非选择性连续78例患者进行128层MSCT冠状动脉成像,其中有15例患者既往置入冠状动脉支架.以选择性冠状动脉造影结果作为评价标准,探讨128层MSCT在诊断冠状动脉疾病及评价支架后再狭窄的临床价值.结果 基于冠状动脉血管节段分析,879个冠状动脉节段中有821节段(93%)进入统计学分析,128层MSCT诊断冠状动脉病变的敏感性87%,特异性97%,阳性预测值83%,阴性预测值97%.对15例共置入22个支架的患者中,有4个(18%)支架MSCT图像显示支架伪影,图像模糊,未能判断支架内血管腔通畅情况,其余18个支架MSCT结果与选择性冠状动脉造影比较,MSCT诊断支架再狭窄的敏感性为100%,特异性77%,阳性预测值63%,阴性预测值100%.结论 128层MSCT冠状动脉成像对冠状动脉疾病的诊断和支架再狭窄的评价具有较高价值,可以作为一项无创检查技术用于对临床怀疑为冠心病的患者进行筛查.

关 键 词:冠状动脉疾病  体层摄影术  X线计算机  支架  冠状动脉造影

Diagnostic value of 128-slice CT coronary angiography in comparison with invasive coronary angiography
CHEN Bu-xing,MA Feng-yun,WEN Zhi-yong,LUO Wei,ZHAO Xi-zhe,KANG Feng,ZHOU Quan-hong,RUAN Jian-hong.Diagnostic value of 128-slice CT coronary angiography in comparison with invasive coronary angiography[J].Chinese Journal of Cardiology,2008,36(3).
Authors:CHEN Bu-xing  MA Feng-yun  WEN Zhi-yong  LUO Wei  ZHAO Xi-zhe  KANG Feng  ZHOU Quan-hong  RUAN Jian-hong
Abstract:Objective To observe the diagnostic value of non-invasive 128-slice computed tomography coronary angiography(CTA)in comparison with invasive coronary angiography.Methods 128-slice CTA and invasive coronary angiography were performed in 78 unselected consecutive patients(63 patients with suspected coronary artery disease and 15 patients with previous coronary stenting,56 males,mean age 61±10 years)and >50% reduction of minimal lumen diameter was defined as significant coronary stenosis.Results Fifty-eight out of 879 segments(7%)from CTA were not assessable because of irreguldr rhythm,vessel calcification or tachycardia.Compared with invasive coronary angiography,segmentbased analysis from the 821 segments showed the sensitivity by CTA was 87%,specificity 97%,PPV 83% and NPV 97%.Four out of 22 stents implanted in 15 patients were not assessable by CTA because of poor image quality.Compared with invasive coronary angiography,the sensitivity of diagnosing in-stent restenosis by CTA was 100%,specificity 77%,PPV 63% and NPV 100% for the remaining 18 stents-Conclusions One hundred and twenty-eight-slice CTA has a high accuracy for detecting coronary artery disease and instent restenosis after coronary stenting and could be considered as a valuable noninvasive technique for screening coronary artery disease in suspected patients.
Keywords:Coronary disease  Tomography  X-ray computed  Stents  Coronary angiography
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号