首页 | 本学科首页   官方微博 | 高级检索  
     


Preclinical evaluation of a novel CEA‐targeting near‐infrared fluorescent tracer delineating colorectal and pancreatic tumors
Authors:Martin C. Boonstra  Berend Tolner  Boudewijn E. Schaafsma  Leonora S.F. Boogerd  Hendrica A.J.M Prevoo  Guarav Bhavsar  Peter J.K. Kuppen  Cornelis F.M. Sier  Bert A. Bonsing  John V. Frangioni  Cornelis J.H. van de Velde  Kerry A. Chester  Alexander L. Vahrmeijer
Affiliation:1. Department of Surgery, Leiden University Medical Center, Leiden, The Netherlands;2. Department of Oncology, Royal Free & University College Medical School, London, United Kingdom;3. Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA;4. Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA;5. Curadel, LLC, Worcester, MA
Abstract:Surgery is the cornerstone of oncologic therapy with curative intent. However, identification of tumor cells in the resection margins is difficult, resulting in nonradical resections, increased cancer recurrence and subsequent decreased patient survival. Novel imaging techniques that aid in demarcating tumor margins during surgery are needed. Overexpression of carcinoembryonic antigen (CEA) is found in the majority of gastrointestinal carcinomas, including colorectal and pancreas. We developed ssSM3E/800CW, a novel CEA‐targeted near‐infrared fluorescent (NIRF) tracer, based on a disulfide‐stabilized single‐chain antibody fragment (ssScFv), to visualize colorectal and pancreatic tumors in a clinically translatable setting. The applicability of the tracer was tested for cell and tissue binding characteristics and dosing using immunohistochemistry, flow cytometry, cell‐based plate assays and orthotopic colorectal (HT‐29, well differentiated) and pancreatic (BXPC‐3, poorly differentiated) xenogeneic human–mouse models. NIRF signals were visualized using the clinically compatible FLARE? imaging system. Calculated clinically relevant doses of ssSM3E/800CW selectively accumulated in colorectal and pancreatic tumors/cells, with highest tumor‐to‐background ratios of 5.1 ± 0.6 at 72 hr postinjection, which proved suitable for intraoperative detection and delineation of tumor boarders and small (residual) tumor nodules in mice, between 8 and 96 hr postinjection. Ex vivo fluorescence imaging and pathologic examination confirmed tumor specificity and the distribution of the tracer. Our results indicate that ssSM3E/800CW shows promise as a diagnostic tool to recognize colorectal and pancreatic cancers for fluorescent‐guided surgery applications. If successfully translated clinically, this tracer could help improve the completeness of surgery and thus survival.
Keywords:CEACAM5  NIR fluorescence  surgery  image guided  clinical translation
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号