首页 | 本学科首页   官方微博 | 高级检索  
     


Hepatocyte growth factor levels in Legionella pneumonia: A retrospective study
Authors:Futoshi Higa  Morikazu Akamine  Makoto Furugen  Kenji Hibiya  Michio Koide  Maki Tamayose  Yuichiro Tamaki  Syusaku Haranaga  Noriko Arakaki  Satomi Yara  Masao Tateyama  Jiro Fujita
Affiliation:1. Translational Research Division, International Vaccine Institute, Seoul, Korea
8. Biocenter, University of Vienna, Vienna, Austria
2. Laboratory Division, Public Health Laboratory (Pemba) - Ivo de Carneri, Chake Chake, Tanzania
3. Amani Centre, National Institute for Medical Research, Tanga, Tanzania
4. Joint Malaria Program, Tanga, Tanzania
5. Asia Pacific Malaria Elimination Network (APMEN), Menzies School of Health Research, Casuarina, Australia
6. Teule Hospital, Muheza, Tanga, Tanzania
7. Oxford Research Unit, Mahidol University, Bangkok, Thailand
Abstract:

Background

Typhoid fever remains a significant health problem in many developing countries. A rapid test with a performance comparable to that of blood culture would be highly useful. A rapid diagnostic test for typhoid fever, Tubex®, is commercially available that uses particle separation to detect immunoglobulin M directed towards Salmonella Typhi O9 lipopolysaccharide in sera.

Methods

We assessed the sensitivity and specificity of the Tubex test among Tanzanian children hospitalized with febrile illness using blood culture as gold standard. Evaluation was done considering blood culture confirmed S. Typhi with non-typhi salmonella (NTS) and non - salmonella isolates as controls as well as with non-salmonella isolates only.

Results

Of 139 samples tested with Tubex, 33 were positive for S. Typhi in blood culture, 49 were culture-confirmed NTS infections, and 57 were other non-salmonella infections. Thirteen hemolyzed samples were excluded. Using all non - S. Typhi isolates as controls, we showed a sensitivity of 79% and a specificity of 89%. When the analysis was repeated excluding NTS from the pool of controls we showed a sensitivity of 79% and a specificity of 97%. There was no significant difference in the test performance using the two different control groups (p > 0.05).

Conclusion

This first evaluation of the Tubex test in an African setting showed a similar performance to those seen in some Asian settings. Comparison with the earlier results of a Widal test using the same samples showed no significant difference (p > 0.05) for any of the performance indicators, irrespective of the applied control group.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号