首页 | 本学科首页   官方微博 | 高级检索  
     

甲醛消除灵消除甲醛效果的实验研究
引用本文:周纯良,吴传业,黄涛,李开宇,卢岚. 甲醛消除灵消除甲醛效果的实验研究[J]. 环境与健康杂志, 2004, 21(1): 56-57
作者姓名:周纯良  吴传业  黄涛  李开宇  卢岚
作者单位:湖南省疾病预防控制中心,湖南,长沙,410005;湖南省疾病预防控制中心,湖南,长沙,410005;湖南省疾病预防控制中心,湖南,长沙,410005;湖南省疾病预防控制中心,湖南,长沙,410005;湖南省疾病预防控制中心,湖南,长沙,410005
摘    要:目的:研究甲醛消除灵对室内空气和木质板材中甲醛的清除效果。方法:(1)室内空气中甲醛的清除试验:选择新装修的办公室2间,1间经甲醛消除灵处理,1间不作处理,比较2个房间的甲醛浓度。(2)木质板材中甲醛的清除试验:采木质板材,1份经甲醛消除灵处理,1份不作处理,同时检测其甲醛释放量。结果经甲醛消除灵处理24、48、72h的房间空气中甲醛的清除率分别为82.94%、91.43%、95.69%,处理72h室内空气甲醛浓度达到国家标准;木质板材经甲醛消除灵处理24、48、72h甲醛的清除率分别为84.71%、90.55%、90.96%,处理24h后木质板材甲醛释放量达到国家标准。结论:甲醛消除灵对室内空气和木质板材中的甲醛均具有明显的消除作用。

关 键 词:空气污染  室内  甲醛  清除率  甲醛消除灵
文章编号:1001-5914(2004)01-0056-02
修稿时间:2003-03-02

Experimental Study on the Removal of Formaldehyde by Formaldehyde-Cleaning Agent
ZHOU Chun-liang,WU Chuan-ye,HUANG Tao,et al.. Experimental Study on the Removal of Formaldehyde by Formaldehyde-Cleaning Agent[J]. Journal of Environment and Health, 2004, 21(1): 56-57
Authors:ZHOU Chun-liang  WU Chuan-ye  HUANG Tao  et al.
Affiliation:ZHOU Chun-liang,WU Chuan-ye,HUANG Tao,et al. Hunan Provincial Center for Disease Control and Prevention,Changsha,Hunan 410005,China
Abstract:Objective To explore the removal effects of formaldehyde from indoor air and plywood by a formaldehyde-cleaning agent. Methods (1)experiment on removal of formaldehyde in indoor air: 2 newly decorated office rooms were selected, the indoor air was treated by formaldehyde-cleaning agent in one test room, and the other was used as control. After treatment, the concentrations of formaldehyde in two office rooms were measured and compared between them. (2)experiment on the removal effects of formaldehyde in plywood. The plywood samples were selected and divided into two groups, one was treated by formaldehyde- cleaning agent as test group, the other as the control. The emisson of formaldehyde from plywood was measured and compared between two groups. Results The removal efficiencies of formaldehyde in indoor air were 82.94%, 91.43%, 95.69%, at the 24th, 48th, 72th hour after the treatment of formaldehyde-cleaning agent respectively. The formaldehyde concentration in indoor air of test room met the requirement of the national standard after 72h-treatment of formaldehyde-cleaning agent. The removal efficiencies of formaldehyde emitted from plywood were 84.71%, 90.55%, 90.96% at the 24th, 48h, 72th hour after the treatment of formaldehyde-cleaning agent respectively. The emission amount of formaldehyde from plywood met the requirement of the national standard after 24h-treatment of formaldehyde-cleaning agent. Conclusion Formaldehyde-clearning agent presented significant removal effects on formaldehyde from indoor air and plywood.
Keywords:Air pollution   indoor: Formaldehyde: Removal efficiency: Formaldehyde-cleaning agent
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号