首页 | 本学科首页   官方微博 | 高级检索  
检索        


Protective ventilation attenuates postoperative pulmonary dysfunction in patients undergoing cardiopulmonary bypass
Authors:Chaney M A  Nikolov M P  Blakeman B P  Bakhos M
Institution:Department of Anesthesia and Critical Care, University of Chicago, IL 60637, USA.
Abstract:OBJECTIVE: To ascertain if protective ventilation can attenuate the damaging postoperative pulmonary effects of cardiopulmonary bypass (increases in airway pressure, decreases in lung compliance, and increases in shunt). DESIGN: Prospective, randomized clinical trial. SETTING: Single university hospital. PARTICIPANTS: Twenty-five patients undergoing elective coronary artery bypass graft procedure and early extubation. INTERVENTIONS: Thirteen patients received conventional mechanical ventilation (CV; respiratory rate, 8 breaths/min; tidal volume, 12 mL/kg; fraction of inspired oxygen FIO2], 1.0; positive end-expiratory pressure PEEP], +5), and 12 patients received protective mechanical ventilation (PV; respiratory rate, 16 breaths/min; tidal volume, 6 mL/kg; FIO2, 1.0; PEEP, +5). Perioperative anesthetic and surgical management were standardized. Various pulmonary parameters were determined twice perioperatively: 10 minutes after intubation and 60 minutes after arrival in the intensive care unit. MEASUREMENTS AND MAIN RESULTS: The mean postoperative increase in peak airway pressure in group CV was significantly larger than the mean postoperative increase in peak airway pressure in group PV (7.1 v 2.4 cm H2O; p < 0.001). Group CV experienced significant postoperative increases in plateau airway pressure (p = 0.007), but group PV did not (p = 0.644). The mean postoperative decrease in dynamic lung compliance in group CV was significantly larger than the mean postoperative decrease in dynamic lung compliance in group PV (14.9 v 5.5 mL/cm H2O; p = 0.002). Group CV experienced significant postoperative decreases in static lung compliance (p = 0.014), but group PV did not (p = 0.645). Group CV experienced significant postoperative increases in shunt (15.5% to 21.4%; p = 0.021), but group PV did not (18.4% to 21.2%; p = 0.265). CONCLUSIONS: Data indicate that protective ventilation decreases pulmonary damage caused by mechanical ventilation in normal and abnormal lungs. The results of this investigation indicate that protective ventilation may also help attenuate the postoperative pulmonary dysfunction (increases in airway pressure, decreases in lung compliance, and increases in shunt) commonly seen in patients after exposure to cardiopulmonary bypass.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号