首页 | 本学科首页   官方微博 | 高级检索  
     

经脾门静脉造影磁共振成像:肝脏灌注均匀度的研究
引用本文:钟群,张雪林,张玉忠,郭涛,昌仁民,苍鹏,陈斌,于丽娟. 经脾门静脉造影磁共振成像:肝脏灌注均匀度的研究[J]. 南方医科大学学报, 2004, 24(2): 216-219
作者姓名:钟群  张雪林  张玉忠  郭涛  昌仁民  苍鹏  陈斌  于丽娟
作者单位:第一军医大学南方医院影像中心,广东,广州,510515;第一军医大学南方医院影像中心,广东,广州,510515;第一军医大学南方医院影像中心,广东,广州,510515;第一军医大学南方医院影像中心,广东,广州,510515;第一军医大学南方医院影像中心,广东,广州,510515;第一军医大学南方医院影像中心,广东,广州,510515;第一军医大学南方医院影像中心,广东,广州,510515;第一军医大学南方医院影像中心,广东,广州,510515
摘    要:目的研究经脾门静脉造影磁共振成像(MRSP)在肝脏非病变区的灌注均匀度。方法可疑肝脏占位性病变患者16例,行MRSP检查。扫描分4个时相:平扫期、门静脉期、实质期和延迟期,测量不同时相肝实质和非病变性异常灌注区信号强度。结果MRSP门脉期出现肝脏非病变区的异常灌注率为4/16,共8个灶,均为肝硬化患者,最多见为三角形或扇形(7/8),分布无规律。结论MRSP在门静脉期存在不均匀灌注,但并不影响对病变的诊断;MRSP可得到较均匀的肝脏门脉期强化。

关 键 词:磁共振成像  门静脉造影术  脾脏  肝脏  灌注均匀度
文章编号:1000-2588(2004)02-0216-04
修稿时间:2003-09-19

Perfusion homogeneity of hepatic parenchyma in magnetic resonance imaging during splenoportography
ZHONG Qun,ZHANG Xue-lin,ZHANG Yu-zhong,GUO Tao,CHANG Ren-min,CANG Peng,CHEN Bin,YU Li-juanMedical Diagnostic Imaging Center,Nanfang Hospital,First Military Medical University,Guangzhou ,China. Perfusion homogeneity of hepatic parenchyma in magnetic resonance imaging during splenoportography[J]. Journal of Southern Medical University, 2004, 24(2): 216-219
Authors:ZHONG Qun  ZHANG Xue-lin  ZHANG Yu-zhong  GUO Tao  CHANG Ren-min  CANG Peng  CHEN Bin  YU Li-juanMedical Diagnostic Imaging Center  Nanfang Hospital  First Military Medical University  Guangzhou   China
Affiliation:ZHONG Qun,ZHANG Xue-lin,ZHANG Yu-zhong,GUO Tao,CHANG Ren-min,CANG Peng,CHEN Bin,YU Li-juanMedical Diagnostic Imaging Center,Nanfang Hospital,First Military Medical University,Guangzhou 510515,China
Abstract:Objective To evaluate the homogeneity of hepatic parenchyma enhancement in magnetic resonance imaging during splenoportography (MRSP) in the portal phase. Methods MRSP was performed in 16 patients suspected of space-occupying lesions in the livers. The signal intensity of non-lesion abnormal perfusion areas and that of peripheral parenchyma were measured in all the scanning phases including unenhanced phase, portographic phase, equilibrium phase, and delayed phase. Results Perfusion abnormalities were observed in 8 non-lesion foci in the portal phase in 4 cases of hepatic cirrhosis, most frequently appearing in triangle or fan-like shapes (7/8) with unpredictable locations. Hepatic cirrhosis patients had more non- lesion perfusion abnormalities than non-cirrhosis patients. Conclusions The presence of non-lesion perfusion abnormalities in MRSP does not affect the diagnosis of the disease, and more homogeneous enhancement of the hepatic parenchyma in the portal phase can be achieved in MRSP than in CT during arterial portography and magnetic resonance imaging during arterial portography.
Keywords:magnetic resonance imaging  portography  spleen  liver  perfusion homogenization
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号