首页 | 本学科首页   官方微博 | 高级检索  
     


The validity of canine platelet aggregometry in predicting vascular graft patency
Authors:H P Greisler  J F McGurrin  J J Klosak  C W Tattersall  J Ellinger  S C Henderson  E A Cabusao
Affiliation:Department of Surgery, Loyola University Medical Center, Maywood, Illinois.
Abstract:Several laboratories have found canine platelet aggregometry predictive of thrombotic potential in vascular grafts. Adenosine diphosphate (ADP) is a frequently used agonist, often at unspecified or differing concentrations. This study was designed to evaluate the predictive value of ADP-induced platelet aggregometry and the validity of the methodology. Platelet aggregometry in response to 2 x 10(-5) M ADP was assayed in 70 dogs. Twenty-six percent were aggregators, 51% were non-aggregators, and 20% were indeterminant. All dogs were then treated with aspirin and dipyridamole. Vascular prostheses were implanted bilaterally (aorto-iliac) and anti-platelet therapy continued for two weeks. Dose-response to ADP was studied at three concentrations in 20 dogs. At 2 x 10(-5) 1/20 aggregated, at 4 x 10(-5) 3/19 aggregated and at 2 x 10(-4) 15/20 aggregated. Time between samples and study was evaluated in 11 dogs, with 2/11 changing from non-aggregator to aggregator at two or three hours. Daily reproducibility was studied in 70 dogs, 14 of which changed aggregation status between days. Patency was 58/68 (85%) for non-aggregators, 23/34 (68%) for aggregators (p = 0.038). Platelet aggregometry has significant predictive value for graft patency but methodology must be specified and standardized.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏