Abstract: | Radiography plays an important role in a neonatal intensive care nursery. Diagnostic radiation was measured in 96 newborns. Mean exposure per neonate was 68.1 milliroentgens (mR) (SD = 132.7) with a median exposure per neonate of 28 mR. Radiation received by neonates was low, but further studies are needed to show the safety of radiation or its delayed effects. The measurement of radiation is simple, and routine radiation recording can prove useful in future evaluations of this high-risk population. |