首页 | 本学科首页   官方微博 | 高级检索  
检索        


The effect of pericardial incision on right ventricular systolic function: a prospective observational study
Authors:Charles J Bitcon  Claude Tousignant
Institution:1.Department of Anesthesia, St Michael’s Hospital,The University of Toronto,Toronto,Canada;2.Department of Anesthesia,St. Vincent’s Hospital,Melbourne,Australia
Abstract:

Background

Echocardiographic longitudinal markers of right ventricular (RV) systolic function are commonly depressed after coronary artery bypass graft surgery (CABG) despite an uncomplicated course and good clinical recovery. The exact timing and cause of these changes is unknown. The aim of this observational study was to monitor echocardiographic markers of RV systolic function intraoperatively during CABG. We used angle-independent speckle tracking to measure the primary endpoints of tricuspid annular plane systolic excursion (TAPSE) and tricuspid annular systolic velocity (S′) before and after pericardiotomy.

Methods

Twenty-four patients undergoing elective on-pump CABG were enrolled in the study. Speckle tracking-derived TAPSE, S’, free wall systolic strain, RV outflow tract strain, colour tissue Doppler-derived isovolumic acceleration (IVA) and two-dimensional RV dimensions and fractional area change (FAC) were measured at three intraoperative time points: 1) after sternotomy immediately prior to pericardiotomy; 2) after pericardiotomy and placement of pericardial retraction sutures; and 3) following cardiopulmonary bypass after chest closure.

Results

Adequate image quality to perform speckle tracking measurements was obtained in twenty-one patients. We found that there were no significant changes to echocardiographic parameters of RV systolic function between pre- and post-pericardiotomy. The mean (SD) of the primary endpoints were: TAPSE 28.1 (5.1) mm vs 27.7 (7.4) mm, respectively; mean difference, ?0.4 mm; 97.5% confidence interval (CI), ?4.0 to 3.1; P = 0.76] and S′ 10.4 (2.1) cm·sec?1 vs 10.8 (1.9) cm·sec?1, respectively; mean difference, 0.4 cm·sec?1; 97.5% CI, ?0.9 to 1.7; P = 0.48]. Significant reductions in the parameters of RV systolic function were found only after cardiopulmonary bypass and chest closure.

Conclusion

Pericardial opening and suspension had no significant effect on the indices of RV systolic function derived from speckle tracking or colour tissue Doppler.
Keywords:
本文献已被 SpringerLink 等数据库收录!