引用本文:张冀,张艳容,陈娟,陈晓惠,钟小丽. 采用自动选择参照图校正肝超声造影图像呼吸运动[J]. 中国生物医学工程学报, 2017, 36(6): 670-677. DOI: 10.3969/j.issn.0258-8021.2017.06.005
作者姓名:张冀  张艳容  陈娟  陈晓惠  钟小丽
作者单位:1武汉大学中南医院医学影像科,武汉 4300702华中科技大学同济医学院附属协和医院超声影像科,武汉 430070
基金项目:国家自然科学基金(81401474)
摘    要:参照图选择是肝超声造影呼吸运动校正方法有效性的关键因素之一,其选择方法值得进一步探索。先采用拉普拉斯特征映射(LE)法将原始高维超声数据降至二维空间,再采用k-means法进行聚类分析,获取理想的超声参照图进行呼吸运动校正,最后在18例兔肝VX2肿瘤超声造影病例上验证并评价该方法的有效性。校正前图像序列的平均结构相似度和平均互相关系数均值分别为0.45±0.11和0.67±0.16,校正后两者均明显增加(P<0.001),分别为0.59±0.11和0.81±0.11。校正前图像序列的偏差值(DV)均值为92.16±18.12,校正后均值下降到约为原值的1/3。结果表明,所提出的呼吸运动校正方法能提高传统依靠人工选择参照面进行超声定量分析方法的准确性,且操作简单,具有一定临床应用潜力。

关 键 词:超声造影  参照图  呼吸运动  流行学习  VX2肿瘤  
收稿时间:2016-07-28

Respiratory Motion Correction of Liver Contrast-Enhanced Ultrasound Sequences by Selecting Reference Image Automatically
Zhang Ji,Zhang Yanrong,Chen Juan,Chen Xiaohui,Zhong Xiaoli. Respiratory Motion Correction of Liver Contrast-Enhanced Ultrasound Sequences by Selecting Reference Image Automatically[J]. Chinese Journal of Biomedical Engineering, 2017, 36(6): 670-677. DOI: 10.3969/j.issn.0258-8021.2017.06.005
Authors:Zhang Ji  Zhang Yanrong  Chen Juan  Chen Xiaohui  Zhong Xiaoli
Affiliation:Zhongnan Hospital of Wuhan University, Department of Medical Imaging, Wuhan 430070, China Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong Universtiy of Science and Technology, Wuhan 430070, China
Abstract:The selection of reference image is one of the key roles for the efficiency of respiratory motion correction method based on liver contrast-enhance ultrasound (CEUS) image sequences. The selection method is worthwhile exploring. First, the original high-dimensional ultrasound data was mapped into a two-dimensional space by using Laplacian eigenmaps. Then, the cluster analysis was adopted using k-means, and the optimal ultrasound reference image was obtained for the respiratory motion correction. Finally, the effectiveness of this proposed method was validated with 18 CEUS cases of VX2 tumor implanted in the rabbit liver. Before correction, the average of total mean structural similarity and the average of mean correlation coefficient from image sequences were 0.45±0.11 and 0.67±0.16,respectively. After correction, the two parameters were increased obviously (P<0.001) as 0.59±0.11 and 0.81±0.11 respectively. The average of deviation valve (DV) from image sequences before correction was 92.16±18.12. After correction, the average of DV was reduced to one-third of the original value. The proposed respiratory motion method improved the accuracy of the quantitative analysis of CEUS by using the reference image based on the traditionally manual selection as well as operated simply, therefore is of potentials in the clinical application.
Keywords:contrast-enhanced ultrasound  reference image  respiratory motion  manifold learning  VX2 tumor  