首页 | 本学科首页   官方微博 | 高级检索  
检索        

Biomechanical study on pullout strength of thoracic extrapedicular screw fixation
作者姓名:付长峰  刘一  张绍昆  宋之明
作者单位:Department of Orthopaedics First Hospital of Jilin University,Changchun 130021,China,Department of Orthopaedics,First Hospital of Jilin University,Changchun 130021,China,Department of Orthopaedics,First Hospital of Jilin University,Changchun 130021,China,Department of Orthopaedics,First Hospital of Jilin University,Changchun 130021,China
摘    要:Objective:To identify the biomechanical feasibility of the thoracic extrapedicular approach to the placement of screws. Methods:Five fresh adult cadaveric thoracic spine from T1 to T8 were harvested. The screw was inserted either by pedicular approach or extrapedicular approach. The result was observed and the pullout strength by pedicular screw approach and extrapedicular screw approach via sagittal axis of the vertebrale was measured and compared statistically. Results:In thoracic pedicular approach, the pullout strength of pedicle screw was 1001.23 N±220 N (288.2-1561.7 N) and that of thoracic extrapedicular screw approach was 827.01 N±260 N when screw was inserted into the vertebrae through transverse process,and 954.25 N±254 N when screw was inserted into the vertebrae through the lateral cortex of the pedicle. Compared with pedicular group, the pullout strength in extrapedicular group was decreased by 4.7% inserted through transverse process (P>0.05) and by 17.3% inserted through the lateral cortex (P<0.05). The mean pullout strength by extrapedicular approach was decreased by 11.04% as compared with pedicular approach (P<0.05). Conclusions:It is feasible biomechanically to use extrapedicular screw technique to insert pedicular screws in the thoracic spine when it is hard to insert by pedicular approach.

关 键 词:脊椎疾病  骨髓  病理  治疗  临床
收稿时间:2005-11-18

Biomechanical study on pullout strength of thoracic extrapedicular screw fixation
FU Chang-feng,LIU Yi,ZHANG Shao-kun,SONG Zhi-ming.Biomechanical study on pullout strength of thoracic extrapedicular screw fixation[J].Chinese Journal of Traumatology(English Edition),2006,9(6):374-376.
Authors:FU Chang-feng  LIU Yi  ZHANG Shao-kun  SONG Zhi-ming
Institution:Department of Orthopaedics, First Hospital of Jilin University, Changchun 130021, China
Abstract:OBJECTIVE: To identify the biomechanical feasibility of the thoracic extrapedicular approach to the placement of screws. METHODS: Five fresh adult cadaveric thoracic spine from T1 to T8 were harvested. The screw was inserted either by pedicular approach or extrapedicular approach. The result was observed and the pullout strength by pedicular screw approach and extrapedicular screw approach via sagittal axis of the vertebrale was measured and compared statistically. RESULTS: In thoracic pedicular approach, the pullout strength of pedicle screw was 1001.23 N+/-220 N (288.2-1561.7 N)ls and that of thoracic extrapedicular screw approach was 827.01 N+/-260 N when screw was inserted into the vertebrae through transverse process, and 954.25 N+/-254 N when screw was inserted into the vertebrae through the lateral cortex of the pedicle. Compared with pedicular group, the pullout strength in extrapedicular group was decreased by 4.7% inserted through transverse process (P larger than 0.05) and by 17.3% inserted through the lateral cortex (P less than 0.05). The mean pullout strength by extrapedicular approach was decreased by 11.04% as compared with pedicular approach (P less than 0.05). CONCLUSIONS: It is feasible biomechanically to use extrapedicular screw technique to insert pedicular screws in the thoracic spine when it is hard to insert by pedicular approach.
Keywords:Spine  Bone screws  Spinal fracture
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号