首页 | 本学科首页   官方微博 | 高级检索  
检索        


Detection and quantification of focal uptake in head and neck tumours: 18F-FDG PET/MR versus PET/CT
Authors:Arthur Varoquaux  Olivier Rager  Antoine Poncet  Bénédicte M A Delattre  Osman Ratib  Christoph D Becker  Pavel Dulguerov  Nicolas Dulguerov  Habib Zaidi  Minerva Becker
Institution:1. Department of Imaging, Divisions of Radiology and Nuclear Medicine, Geneva University Hospital, Rue Gabrielle Perret Gentil 4, CH-1211, Geneva 14, Switzerland
2. Center for Clinical Research, Geneva University Hospital, Geneva, Switzerland
3. Nuclear Medicine Division, Philips Healthcare AG, Gland, Switzerland
4. Clinic of Otorhinolaryngology Head and Neck Surgery, Geneva University Hospital, Geneva, Switzerland
Abstract:

Purpose

Our objectives were to assess the quality of PET images and coregistered anatomic images obtained with PET/MR, to evaluate the detection of focal uptake and SUV, and to compare these findings with those of PET/CT in patients with head and neck tumours.

Methods

The study group comprised 32 consecutive patients with malignant head and neck tumours who underwent whole-body 18F-FDG PET/MR and PET/CT. PET images were reconstructed using the attenuation correction sequence for PET/MR and CT for PET/CT. Two experienced observers evaluated the anonymized data. They evaluated image and fusion quality, lesion conspicuity, anatomic location, number and size of categorized (benign versus assumed malignant) lesions with focal uptake. Region of interest (ROI) analysis was performed to determine SUVs of lesions and organs for both modalities. Statistical analysis considered data clustering due to multiple lesions per patient.

Results

PET/MR coregistration and image fusion was feasible in all patients. The analysis included 66 malignant lesions (tumours, metastatic lymph nodes and distant metastases), 136 benign lesions and 470 organ ROIs. There was no statistically significant difference between PET/MR and PET/CT regarding rating scores for image quality, fusion quality, lesion conspicuity or anatomic location, number of detected lesions and number of patients with and without malignant lesions. A high correlation was observed for SUVmean and SUVmax measured on PET/MR and PET/CT for malignant lesions, benign lesions and organs (ρ?=?0.787 to 0.877, p?<?0.001). SUVmean and SUVmax measured on PET/MR were significantly lower than on PET/CT for malignant tumours, metastatic neck nodes, benign lesions, bone marrow, and liver (p?<?0.05). The main factor affecting the difference between SUVs in malignant lesions was tumour size (p?<?0.01).

Conclusion

In patients with head and neck tumours, PET/MR showed equivalent performance to PET/CT in terms of qualitative results. Comparison of SUVs revealed an excellent correlation for measurements on both modalities, but underestimation of SUVs measured on PET/MR as compared to PET/CT.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号