首页 | 本学科首页   官方微博 | 高级检索  
检索        


Independent measures of insulin secretion and insulin sensitivity during the same test: the glucagon-insulin tolerance test
Authors:Dorkhan M  Tripathy D  Malm G  Asgharian H  Tuomi T  Groop L
Institution:From theDivision of Diabetes &Endocrinology, Department of Clinical Sciences, Lund University, MalmöUniversity Hospital, Malmö, Sweden;, Division of Diabetes, University of Texas Health Sciences Center at San Antonio, San Antonio, TX, USA;, Primary Health Care, Skåne Southwest, Health Care Centre Eden, Malmö;;Department of Economics, Lund University, Lund;Sweden;;Department of Medicine, Helsinki University Central Hospital;;and Folkhalsan Genetic Institute, Folkhalsan Research Center;and Research Program for Molecular Medicine, University of Helsinki;Helsinki, Finland
Abstract:Background. To validate a test for independent assessment of insulin secretion and insulin sensitivity during the same occasion for metabolic studies in clinical practice, i.e. combined glucagon‐stimulated C‐peptide test and insulin tolerance test (GITT). Subjects and methods. We measured C‐peptide response to 0.5 mg of intravenous glucagon followed 30 min later by administration of 0.05 U kg?1 insulin (insulin tolerance test, ITT). Ten subjects with normal glucose tolerance participated on different days in an ITT, glucagon‐C‐peptide test, ITT followed by glucagon‐C‐peptide test and glucagon‐C‐peptide test followed by ITT to establish whether and how the tests could be combined. The test was then repeated in nine patients with type 2 diabetes to investigate its reproducibility. In 20 subjects with varying degrees of glucose tolerance, the test was compared with the Botnia clamp (an intravenous glucose tolerance test combined with a euglycaemic hyperinsulinemic clamp). Results. When ITT preceded the glucagon test, C‐peptide response was blunted. Therefore, we first administered glucagon and then insulin (GITT). The KITT from the GITT was reproducible (CV = 13 %) and correlated strongly with the glucose disposal rate from the Botnia clamp (r = 0.87, r2 = 0.75, P < 0.001). The C‐peptide response to glucagon was reproducible (CV = 13 %). The disposition index, providing a measure of beta‐cell function adjusted for insulin sensitivity, calculated from the GITT showed good discrimination between individuals with varying degrees of glucose tolerance. Conclusions. The GITT provides simple, reproducible and independent estimates of insulin sensitivity and secretion on the same occasion for metabolic studies in individuals with normal and abnormal glucose tolerance.
Keywords:disposition index  euglycaemic clamp  insulin secretion  insulin sensitivity  insulin tolerance test  type 2 diabetes
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号