首页 | 本学科首页   官方微博 | 高级检索  
     


Volare winkelstabile vs. dorsale Plattenosteosynthese bei der distalen Radiusextensionsfraktur
Authors:Dr. R.P. Zettl  E. Clauberg  D. Nast-Kolb  S. Ruchholtz  C.A. Kühne
Affiliation:1. Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universit?tsklinikum Giessen und Marburg, Philipps-Universit?t Marburg, Baldingerstra?e, 35043, Marburg, Deutschland
2. Klinik für Unfallchirurgie, Universit?tsklinikum Essen, Essen, Deutschland
Abstract:

Introduction

This study investigated the radiographic and functional outcomes of two different methods for treating fractures of the distal part of the radius.

Patients and methods

In a prospective controlled study patients with forearm fractures were randomized by age, handedness, and fracture type.

Results

The study included 120 patients, with a mean age of 66 years. Forty-nine percent of the fractures were extraarticular, and 51% were intraarticular. In the group treated with volar locking compression plates, six patients needed operative decompression of the median nerve and one needed reconstruction of the extensor pollicis longus (EPL) tendon. The group with dorsal plating had three complications requiring operative treatment: one deep infection, one dislocation of the plate, and one reconstruction of the EPL tendon. The radiological results for the Stewart 1 score showed 68% excellent results in volar locking compression plating compared with 57% in dorsal plating. Regarding functional outcome, 48% with volar plating showed excellent results compared with 22% with dorsal plating, as measured by the Stewart 2 score.

Conclusion

Despite significant advantages of the volar locked compression plating, subjective satisfaction did not differ between the two groups.
Keywords:
本文献已被 SpringerLink 等数据库收录!