Beagle犬血浆中辛伐他汀的LC-MS测定
引用本文:张怡,李中东,郁韵秋,施孝金,钟明康.Beagle犬血浆中辛伐他汀的LC-MS测定[J].中国医药工业杂志,2008,39(9).
作者姓名:张怡  李中东  郁韵秋  施孝金  钟明康
作者单位:1. 复旦大学附属华山医院临床药学研究室,上海,200040
2. 复旦大学药学院药物分析教研室,上海,200032
摘    要:建立了LC-MS法测定Beagle犬血浆中的辛伐他汀。采用C_(18)柱,流动相为乙腈-0.1%甲酸溶液(60:40),以洛伐他汀为内标,采用电喷雾离子化法(ESI)采集正离子,单离子方式检测m/z 419(辛伐他汀)和m/z 405(洛伐他汀)。辛伐他汀在0.5~160ng/ml浓度范围内线性良好,检测限为0.25ng/ml。血浆样品的日内、日间RSD均小于7.7%,方法回收率为92.2%~99.2%,提取回收率为92.8%~100.9%。

关 键 词:辛伐他汀  血浆  电喷雾离子化  液相色普-质谱  测定

Determination of Simvastatin in Beagle Dogs Plasma by LC-MS
Authors:ZHANG Yi  LI Zhong-dong  YU Yun-qiu  SHI Xiao-jin  ZHONG Ming-kang
Abstract:A LC-MS method was established for the determination of simvastatin in Beagle dogs plasma.A C_(18)column was used with the mobile phase of acetonitrile-0.1% formic acid solution(60:40).Lovastatin was used as the internal standard.ESI was applied and operated in single ion monitoring(SIM)mode for the determination of positive ions at m/z 419(simvastatin)and m/z 405(lovastatin).The calibration curve of simvastatin was linear in the concentration range of 0.5-160ng/ml and the detection limit was 0.25ng/ml.The RSDs of inter-and intra-day were less than 7.7% and the recoveries were 92.2%-99.2%.The extraction recoveries of simvastatin were 92.8%-100.9%.
Keywords:simvastatin  plasma  electrospray ionization  LC-MS  determination