722实时动态胰岛素泵系统治疗2型糖尿病高血糖患者疗效观察
引用本文:唐建东,李清楚,康志强,任健,李蕾,毕健锟. 722实时动态胰岛素泵系统治疗2型糖尿病高血糖患者疗效观察[J]. 中华临床医师杂志(电子版), 2014, 0(21): 34-37
作者姓名:唐建东  李清楚  康志强  任健  李蕾  毕健锟
作者单位:450007,郑州大学附属郑州中心医院内分泌科
摘    要:目的评价722实时动态胰岛素泵系统治疗2型糖尿病高血糖患者疗效。方法 2013年5至11月住院的36例2型糖尿病高血糖患者,给予722实时动态胰岛素泵系统治疗,根据实时血糖监测情况及时调整胰岛素泵用量。结果 (1)722实时动态胰岛素泵系统监测的血糖值与指端毛细血管血糖值呈显著正相关(r=0.97,P<0.01);(2)第3天的日内平均血糖(MBG)、平均血糖波动幅度(MAGE)、有效血糖波动频率(FGE)、日间血糖平均绝对差(MODD)、血糖漂移时间百分比(TBG≥10 mmol/L和TBG≤3.9 mmol/L)均较第1天明显下降(P<0.05);(3)第3天高血糖报警次数及持续时间较第1天明显减少(P<0.01),低血糖报警次数较前无明显变化(P>0.05),但低血糖报警持续时间较前明显减少(P<0.01)。结论 722实时动态胰岛素泵系统能实时显示血糖变化值,治疗2型糖尿病高血糖安全有效。

关 键 词:糖尿病,2型  实时动态胰岛素泵系统

Investigate the effects of Medtronic paradigm 722 real-time insulin pump system in hyperglycaemia patients with type 2 diabetes
Tang Jiandong,Li Qingchu,Kang Zhiqiang,Ren Jian,Li Lei,Bi Jiankun. Investigate the effects of Medtronic paradigm 722 real-time insulin pump system in hyperglycaemia patients with type 2 diabetes[J]. Chinese Journal of Clinicians(Electronic Version), 2014, 0(21): 34-37
Authors:Tang Jiandong  Li Qingchu  Kang Zhiqiang  Ren Jian  Li Lei  Bi Jiankun
Affiliation:.(Department of Endocrinology, Zhengzhou Central Hospital Affiliated to Zhengzhou University, Zhengzhou 450007, China)
Abstract:Objective To investigate the effects of Medtronic paradigm 722 real-time insulin pump system in hyperglycaemia patients with type 2 diabetes. Methods Thirty-six cases of diabetic hyperglycaemia patients between May 2013 and November 2013 underwent Medtronic paradigm 722 real-time insulin pump system. According to real time glucose levels and blood glucose profiles, we made treatments and adjusted the dose of insulin. Results (1) The correlation coefficient between Medtronic paradigm 722 real-time insulin pump system and capillary glucose values was 0.97(P〈0.01); (2) The mean blood glucose (MBG), mean amplitude of glycemic excursions (MAGE), effective blood glucose fluctuations in frequency(FGE), absolute means of daily difference(MODD), the percentage of hyperglycaemia time(TBG≥10 retool/L) and the percentage of hypoglycemia time(TBG≤3.9 retool/L) of the third day were reduced significantly versus the first day(P〈0.01); (3) The hyperglycaemia warning times and persistence times of the third day were significantly decreased versus the first day(P〈0.01), the hypoglycemia warning times were not obvious changed versus the first day(P〉 0.05), but the hypoglycemia persistence times of the third day were significantly decreased versus the first day(P〈0.01). Conclusion Medtronic paradigm 722 real-time insulin pump system can reflect blood glucose profiles, it is safer and effective in treatment of the hyperglycaemia patients with type 2 diabetes.
Keywords:Diabetes mellitus,type 2  Real-time insulin pump system
本文献已被 维普 等数据库收录!