首页 | 本学科首页   官方微博 | 高级检索  
检索        


Why Is a b-value Range of 1500–2000 s/mm2 Optimal for Evaluating Prostatic Index Lesions on Synthetic Diffusion-Weighted Imaging?
Authors:So Yeon Cha  EunJu Kim  Sung Yoon Park
Institution:1.Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.;2.Philips Healthcare, Seoul, Korea.
Abstract:ObjectiveIt is uncertain why a b-value range of 1500–2000 s/mm2 is optimal. This study was aimed at qualitatively and quantitatively analyzing the optimal b-value range of synthetic diffusion-weighted imaging (sDWI) for evaluating prostatic index lesions.Materials and MethodsThis retrospective study included 92 patients who underwent DWI and targeted biopsy for magnetic resonance imaging (MRI)-suggested index lesions. We generated sDWI at a b-value range of 1000–3000 s/mm2 using dedicated software and true DWI data at b-values of 0, 100, and 1000 s/mm2. We hypothesized that lesion conspicuity would be best when the background (i.e., MRI-suggested benign prostatic bP] and periprostatic pP] regions) signal intensity (SI) is suppressed and becomes homogeneous. To prove this hypothesis, we performed both qualitative and quantitative analyses. For qualitative analysis, two independent readers analyzed the b-value showing the best visual conspicuity of an MRI-suggested index lesion. For quantitative analysis, the readers assessed the b-value showing the same bP and pP region SI. The 95% confidence interval (CI) or interquartile range of qualitatively and quantitatively selected optimal b-values was assessed, and the mean difference between qualitatively and quantitatively selected b-values was investigated.ResultsThe 95% CIs of optimal b-values from qualitative and quantitative analyses were 1761–1805 s/mm2 and 1640–1771 s/mm2 (median, 1790 s/mm2 vs. 1705 s/mm2; p = 0.003) for reader 1, and 1835–1895 s/mm2 and 1705–1841 s/mm2 (median, 1872 s/mm2 vs. 1763 s/mm2; p = 0.022) for reader 2, respectively. Interquartile ranges of qualitatively and quantitatively selected optimal b-values were 1735–1873 s/mm2 and 1573–1867 s/mm2 for reader 1, and 1775–1945 s/mm2 and 1591–1955 s/mm2 for reader 2, respectively. Bland–Altman plots consistently demonstrated a mean difference of less than 100 s/mm2 between qualitatively and quantitatively selected optimal b-values.Conclusionb-value range showing a homogeneous background signal may be optimal for evaluating prostatic index lesions on sDWI. Our qualitative and quantitative data consistently recommend b-values of 1500–2000 s/mm2.
Keywords:Prostate  Magnetic resonance imaging  Diffusion  Neoplasm
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号