首页 | 本学科首页   官方微博 | 高级检索  
     

高频条件下(7 MHz)SonoVue与Sonazoid剂量变化对兔肝造影效能的比较
引用本文:郭辉,李安华,刘隆忠,郑玮. 高频条件下(7 MHz)SonoVue与Sonazoid剂量变化对兔肝造影效能的比较[J]. 中华医学超声杂志(电子版), 2011, 8(3): 11-14. DOI: 10.3877/cma.j.issn.1672-6448.2011.03.005
作者姓名:郭辉  李安华  刘隆忠  郑玮
作者单位:1. 中山大学附属第五医院超声科,珠海,519000
2. 中山大学附属肿瘤防治中心超声科
摘    要:
目的 比较高频条件下(7 MHz)不同剂量的两种超声造影剂SonoVue和Sonazoid的显影效果。方法 在相同发射频率(7 MHz)和机械指数(SonoVue为0.25, Sonazoid为0.40)下,分别对8只新西兰大白兔多次团注不同剂量的SonoVue及Sonazoid,应用时间-强度曲线做定量分析,并统计兔肝增强的灌注参数与造影剂剂量的相关性。结果 SonoVue组随着造影剂剂量的增加,其时间-强度曲线的上升时间(RT)、达峰时间(TTP)、平均通过时间(mTT)未见明显变化,其峰值强度(PI)于SonoVue剂量为0.18 mL/kg时达最大值。Sonazoid组mTT随着造影剂剂量的增加而浮动;RT、TTP在Sonazoid剂量为0.015、0.03 mL/kg时为最高值(R2=0.39),且随着造影剂剂量的增加呈下降趋势;PI随着造影剂剂量的增加而逐渐增加。结论 SonoVue和Sonazoid的理化特性不同,在高频条件下(7 MHz)其超声造影效能各不相同。

关 键 词:超声检查;造影剂;频率;剂量

Comparison of the dose changes of SonoVue and Sonazoid to imaging effect of rabbit liver in the high-frequency(7 MHz) state
GUO Hui,LI An-hua,LIU Long-zhong,ZHENG Wei. Comparison of the dose changes of SonoVue and Sonazoid to imaging effect of rabbit liver in the high-frequency(7 MHz) state[J]. Chinese Journal of Medical Ultrasound, 2011, 8(3): 11-14. DOI: 10.3877/cma.j.issn.1672-6448.2011.03.005
Authors:GUO Hui  LI An-hua  LIU Long-zhong  ZHENG Wei
Affiliation:GUO Hui,LI An-hua,LIU Long-zhong,ZHENG Wei.Department of the fifth affiliated hospital of Sun Yat-Sen university,Zhuhai 519000,China
Abstract:
Objective Contrast enhancement of SonoVue and Sonazoid were compared in rabbit liver at frequency of 7 MHz by ultrasound using an imaging dose ranging from 0.015 to 0.24 mL/kg.Method Eight rabbits(weight 2.30±0.30 kg) were injected with the two contrast agents in 7-8 dosage bolus level.Quantitative analysis was done by using time-intensity curve(TIC) to correlate the concentration of the agents and perfusion parameters.Result With the same frequency and a mechanical index was adapted for each agent(mechanical index is 0.25 for SonoVue and 0.4 for Sonazoid):(1) SonoVue group:rise time(RT),time to peak(TTP) and mean transit time(mTT) did not change significantly along with an increase of dose;at 0.18 mL/kg,peak intensity(PI) reached to maximum.(2) Sonazoid group:RT and TTP climbed to peak(0.015mL/kg,0.03 mL/kg) along with an increase of dose and mTT varied significantly with imaging dose.PI increased with the dose.Conclusion Due to the different physical and chemical properties,the two ultrasonic contrast agents have different imaging effects in the high-frequency(7 MHz) state.
Keywords:Ultrasonography  Contrast media  Frequency  Dose  
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《中华医学超声杂志(电子版)》浏览原始摘要信息
点击此处可从《中华医学超声杂志(电子版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号