首页 | 本学科首页   官方微博 | 高级检索  
检索        


Validity of five foot and ankle specific electronic patient-reported outcome (ePRO) instruments in patients undergoing elective orthopedic foot or ankle surgery
Authors:Mikko M Uimonen  Ville T Ponkilainen  Alar Toom  Mikko Miettinen  Arja H Häkkinen  Henrik Sandelin  Antti O Latvala  Timo Sirola  Mika Sampo  Risto P Roine  Jan Lindahl  Outi Ilves  Anna Sandbacka  Jussi P Repo
Institution:1. Department of Surgery, Central Finland Central Hospital, Jyväskylä, Finland;2. Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland;3. Department of Physical Medicine, Central Finland Healthcare District, Jyväskylä, Finland;4. Department of Orthopedics and Traumatology, Helsinki University Hospital and University of Helsinki, Helsinki, Finland;5. Division of Orthopedic and Trauma Surgery, Department of Surgery, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Oulu, Finland;6. Comprehensive Cancer Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland;7. Group Administration, University of Helsinki and Helsinki University Hospital, HUS, Helsinki, Finland;8. Department of Health and Social Management, University of Eastern Finland, Kuopio, Finland
Abstract:BackgroundPatient-reported outcomes (PROs) are widely accepted measures for evaluating outcomes of surgical interventions. As patient-reported information is stored in electronic health records, it is essential that there are valid electronic PRO (ePRO) instruments available for clinicians and researchers. The aim of this study was to evaluate the validity of electronic versions of five widely used foot and ankle specific PRO instruments.MethodsAltogether 111 consecutive elective foot/ankle surgery patients were invited face-to-face to participate in this study. Patients completed electronic versions of the Foot and Ankle Ability Measure (FAAM), the Foot and Ankle Outcome Score (FAOS), the modified Lower Extremity Function Scale (LEFS), the Manchester–Oxford Foot Questionnaire (MOXFQ), and the Visual Analogue Scale Foot and Ankle (VAS-FA) on the day of elective foot and/or ankle surgery. Construct validity, coverage, and targeting of the scales were assessed.ResultsBased on general and predefined thresholds, construct validity, coverage, and targeting of the ePRO versions of the FAAM, the FAOS, the MOXFQ, and the VAS-FA were acceptable. Major issues arose with score distribution and convergent validity of the modified LEFS instrument.ConclusionsThe ePRO versions of the FAAM, the FAOS, the MOXFQ, and the VAS-FA provide valid scores for foot and ankle patients. However, our findings do not support the use of the modified LEFS as an electronic outcome measure for patients with orthopedic foot and/or ankle pathologies.
Keywords:ePRO  Foot  Ankle  Validation  Psychometrics  Clinimetrics  Patient-reported outcome
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号