首页 | 本学科首页   官方微博 | 高级检索  
     


Stepwise approach to substrate modification of ventricular tachycardia after myocardial infarction
Authors:Li Yi-gang  Grönefeld Gerian  Israel Carsten  Lu Shang-biao  Wang Qun-shan  Meng Shu  Hohnloser Stefan H
Affiliation:1. Department of Cardiology, Xinhua Hospital, Shanghai Jiao Tong University, Shanghai 200092, China
2. Department of Medicine, Division of Cardiology, J. W. Goethe University, Frankfurt, Germany
Abstract:Background Recently, substrate mapping (SM) has been described to facilitate catheter ablation of stable and unstable ventricular tachycardia (VT) after myocardial infarction. However, SM is time consuming with potential disadvantages of multiple ablation lines such as impairment of ventricular function or proarrhythmia. The aim of the present study was to delineate a stepwise approach to SM to shorten procedure time and limit the possibility of complications.Methods SM was performed in 14 infarct survivors referred for VT ablation using an electroanatomical mapping system (CARTO) to define infarct regions. A new stepwise approach for SM was designed as follows. The initial ablation site was identified by pace- and entrainment mapping in case of stable VT and by pace mapping only in case of unstable VT. Based on the CARTO voltage mapping, linear ablation was done from this site to the center of the scar and perpendicular to the boundary of the scar or to the mitral annulus. Additional lines were performed only when VT remained inducible. A maximum of 3 ablation lines were created during one procedure. Results A total of 57 VTs (21 stable, 36 unstable) were induced during the procedures. VT was no longer inducible after the first linear ablation in 2 patients, after the second linear ablation in 6 patients and after the third linear ablation in 3 patients. Either VT or ventricular fibrillation was still inducible at the end of the procedure in 3 patients. Procedure time averaged (291±85) minutes, fluoroscopy time (10±7) minutes. VT recurred in 3 patients. Following a second procedure in 2 patients, there were no further VT recurrences. Overall, there was a significant reduction in VT episodes 3 months after [median: 0, interquartile ranges (IQR): 0-1] compared with 3 months before ablation (median: 25, IQR: 16-105, P<0.01). Conclusions This stepwise approach to SM is effective in facilitating ablation of stable and unstable VT. It reduces procedure and fluoroscopy time, and may help to improve the risk-benefit ratio of VT ablation.
Keywords:ventricular tachycardia   mapping   ablation   substrate modification
本文献已被 CNKI 万方数据 PubMed 等数据库收录!
点击此处可从《中华医学杂志(英文版)》浏览原始摘要信息
点击此处可从《中华医学杂志(英文版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号