首页 | 本学科首页   官方微博 | 高级检索  
     

多层螺旋CT曲面重建技术在正常阑尾显示中的应用价值
引用本文:陈英敏,李宝山,刘蓉辉,刘连祥.多层螺旋CT曲面重建技术在正常阑尾显示中的应用价值[J].中国医学影像技术,2006,22(1):111-113.
作者姓名:陈英敏  李宝山  刘蓉辉  刘连祥
作者单位:河北省人民医院医学影像中心,河北,石家庄,050051
基金项目:河北省2005年医学科学研究重点课题(05390)。
摘    要:目的探讨16层螺旋CT曲面重建技术(CPR)在正常阑尾显示中的应用价值。方法应用16层螺旋CT对129位正常受试者进行检查。分别由三位熟悉阑尾CT解剖的观察者寻找阑尾,由其中一位观察者进行曲面重建,在重建后图像上应用单层CPR示踪阑尾,得到CPR像。应用组内相关系数(ICC)评价CPR阑尾径线测量的可重复性。应用CPR与多平面重建(MPR)图像对照及铜线模拟阑尾的方法评价CPR上阑尾径线测量的真实性。结果Kappa检验结果显示不同观察者之间阑尾的检出率及CPR图像质量评价具有极佳的一致性。CPR显示阑尾全貌观察者之间ICC为0.98;观察者内部ICC为0.99,均有很好的可重复性。阑尾中部外径测量及铜线模拟阑尾实验结果显示CPR测量具有高度的真实性。结论CPR对阑尾全貌有很好的显示能力,并可以用于测量阑尾径线。

关 键 词:体层摄影术  X线计算机  曲面重建  阑尾
文章编号:1003-3289(2006)01-0111-03
收稿时间:2005-08-25
修稿时间:2005-11-02

Curved planar reformation of multislice CT in displaying normal appendix
CH EN Ying-min,LI Bao-shan,LIU Rong-hui and LIU Lian-xiang.Curved planar reformation of multislice CT in displaying normal appendix[J].Chinese Journal of Medical Imaging Technology,2006,22(1):111-113.
Authors:CH EN Ying-min  LI Bao-shan  LIU Rong-hui and LIU Lian-xiang
Affiliation:Medical Image Center,Hebei Provincial People's Hospital,Shi jiazhuang 050051,China;Medical Image Center,Hebei Provincial People's Hospital,Shi jiazhuang 050051,China;Medical Image Center,Hebei Provincial People's Hospital,Shi jiazhuang 050051,China;Medical Image Center,Hebei Provincial People's Hospital,Shi jiazhuang 050051,China
Abstract:Objective To evaluate the value of curved planar reformation (CPR) in 162slice CT of normal veriform appen-dix. Methods One hundred and twenty2nine healthy adult s were examined , the reconst ructed data were t ransferred to the workstation. Three observers who were familiar with CT anatomy of veriform appendix looked for the appendix. One ob-server t raced the appendix in multiplanar reformations (MPR) images with single2slice CPR and got the CPR images. Int ra-class correlation coefficient ( ICC) was used to estimate the reliability of measurement and f requency of visualization of appen-dixes. The validity of CPR for appendix was evaluated with copper2line simulated appendix experiment and comparison of the CPR and MPR images. Results The f requency of visualization of appendix of three observers was 93.02%,92. 25 % ,92. 25 % , respectively. 87. 6 % of appendixes were found by all the three observers. The Kappa test showed excellent relia-bility among the three observers. The int rarater ICC for quality of CPR images was 0. 98 , the interrater ICC for that was 0. 99 (P<0.05). The outer diameters of appendixes was (6. 1 ±2. 2) mm , (6.0±2.0) mm separately in CPR and MPR im-ages. No significant difference was found between the group s (P<0.05). The mean length of cooper2lines measured with vernier caliper before and af ter bending was (7.47 ±1.43) mm. The mean length of cooper2lines in CPR was(7.44±1.39)mm. There was no significant difference between the two group s (P<0.05). Conclusion CPR is good for showing the ap-pendix , and can be used in the measurement of appendix.
Keywords:Tomography  X-ray computed  Curved planar reformation  Appendix  