首页 | 本学科首页   官方微博 | 高级检索  
     

Real-time Three-Dimensional Color Doppler Flow Imaging: An Improved Technique for Quantitative Analysis of Aortic Regurgitation
引用本文:吕清 刘夏天 谢明星 王新房 王静 庄磊. Real-time Three-Dimensional Color Doppler Flow Imaging: An Improved Technique for Quantitative Analysis of Aortic Regurgitation[J]. 华中科技大学学报(医学英德文版), 2006, 26(1): 148-152. DOI: 10.1007/BF02828064
作者姓名:吕清 刘夏天 谢明星 王新房 王静 庄磊
作者单位:Department of Echocardiography , Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
摘    要:The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF.

关 键 词:三维彩色多普勒检查 成像技术 主动脉疾病 超声心动图
收稿时间:2005-12-27

Real-time three-dimensional color doppler flow imaging: An improved technique for quantitative analysis of aortic regurgitation
Lu Qing,Liu Xiatian,Xie Mingxing,Wang Xinfang,Wang Jing,Zhuang Lei. Real-time three-dimensional color doppler flow imaging: An improved technique for quantitative analysis of aortic regurgitation[J]. Journal of Huazhong University of Science and Technology. Medical sciences, 2006, 26(1): 148-152. DOI: 10.1007/BF02828064
Authors:Lu Qing  Liu Xiatian  Xie Mingxing  Wang Xinfang  Wang Jing  Zhuang Lei
Affiliation:Department of Echocardiography , Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
Abstract:Summary The recently introduced real-time three-dimensional color Doppler flow imaging RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r=0.93, Y=0.89X+3.9, SEE=8.6 mL,P<0.001); the mean (SD) difference between the two methods was-1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+14.8, SEE=6.4%,P<0.001); the mean (SD) difference between the two methods was-1.2 (7.9)%. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF. Lu Qing, male, born in 1965, Associate Professor
Keywords:real-time three-dimensional echocardiography  color Doppler flow imaging  aortic regurgitation
本文献已被 维普 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号