首页 | 本学科首页   官方微博 | 高级检索  
检索        

导管相关性血流感染预防措施依从性调查及执行效果评价
引用本文:邵文博,王蕾,蔡虻,李燕明,王琢非,刘聚源,李娜,孙晓辉.导管相关性血流感染预防措施依从性调查及执行效果评价[J].中国医药导报,2014(25):99-101,106.
作者姓名:邵文博  王蕾  蔡虻  李燕明  王琢非  刘聚源  李娜  孙晓辉
作者单位:北京医院医院感染管理处
基金项目:北京医院院级科研课题(编号Bj-2012-129)
摘    要:目的了解成人监护中心静脉导管相关血流感染(CLABSI)的集束化预防措施依从性现状,并评价其执行效果。方法对2012年10月~2013年6月入住外科监护室(SICU)、急诊监护室(EICU)、心脏监护室(CCU)和呼吸监护室(RCU)时间〉48 h的病例进行目标性监测,填写CLABSI相关监测信息并如实填写临床对于置管患者执行5大循证预防措施的情况,包括手卫生、置管时最大无菌屏障、2.0%氯己定皮肤消毒、选取适宜置管部位和每日评估尽早拔管。比较各监护室预防措施依从性及CLABSI感染率。结果各监护室对预防措施总依从性为74.5%,CLABSI感染率为6.4‰;其中,RCU预防措施依从性最低(60.2%),感染率最高(10.5‰);SICU预防措施依从性最高(84.4%),感染率最低(2.1‰),差异有统计学意义(P〈0.05)。结论目标性监测和有效的干预可以减少CLABSI的发生率。

关 键 词:中心静脉导管相关血流感染  目标性监测  预防措施  依从性现状

Investigation of the compliance of preventive measures of catheter-related bloodstream infections and evaluation of the practices
SHAO Wenbo;WANG Lei;CAI Meng;LI Yanming;WANG Zhuofei;LIU Juyuan;LI Na;SUN Xiaohui.Investigation of the compliance of preventive measures of catheter-related bloodstream infections and evaluation of the practices[J].China Medical Herald,2014(25):99-101,106.
Authors:SHAO Wenbo;WANG Lei;CAI Meng;LI Yanming;WANG Zhuofei;LIU Juyuan;LI Na;SUN Xiaohui
Institution:SHAO Wenbo;WANG Lei;CAI Meng;LI Yanming;WANG Zhuofei;LIU Juyuan;LI Na;SUN Xiaohui;Hospital Infection Management, Beijing Hospital;
Abstract:Objective To understand the compliance status of cluster prevention of central line associated bloodstream infection (CLABSI) in adult intensive care unit, and to evaluate the effects of execution. Methods By means of the tar-geted surveillance method, the targeted surveillance was performed for patients who were hospitalized the SICU, EICU, CCU and RCU for more than 48 hours from October 2012 to June 2013. Then filled the CLABSI monitoring information and the compliance of 5 evidence-based preventive practices, which included hand hygiene, maximum sterile barrier, 2% chlorhexidine skin disinfection, daily evaluation and promptly remove any intravascular catheter that is no longer essential. The compliance of preventive measures and the infection incidence of CLABSI were compared. Results The compliance status of the preventive measures was 74.5%, the incidence rates of CLABSI was 6.4‰; the lowest compli-ance of preventive measures was RCU which was 60.2%, meanwhile, the infection incidence of RCU was the highest , which was 10.5‰; SICU had the highest compliance of preventive measures, which was 84.4%, and the infection inci-dence rates was the lowest, which was 2.1‰.(P〈 0.05). Conclusion The targeted monitoring and the effectively pre-venting can reduce the incidence rates of CLABSI.
Keywords:Catheter related bloodstream infection  Targeted surveillance  Preventive bundle  Compliance status
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号