Recommendations for the use of sensor‐augmented pumps with predictive low‐glucose suspend features in children: The importance of education
Authors:Andrea E Scaramuzza  Claudia Arnaldi  Valentino Cherubini  Elvira Piccinno  Ivana Rabbone  Sonia Toni  Stefano Tumini  Gilberto Candela  Paola Cipriano  Lucia Ferrito  Lorenzo Lenzi  Davide Tinti  Ohad Cohen  Fortunato Lombardo
Institution:1. Division of Pediatrics, ASST Cremona, “Ospedale Maggiore di Cremona,”, Cremona, Italy;2. UOS Diabetologia Pediatrica ASL Viterbo, Viterbo, Italy;3. Division of Pediatric and Adolescent Diabetes, Department of Women's and Children's Health, AOU Salesi Hospital, Ancona, Italy;4. Division of Pediatric and Adolescent Endocrinology and Diabetes, Hospital Giovanni XXIII, Bari, Italy;5. Department of Pediatrics, University of Turin, Turin, Italy;6. Juvenile Diabetes Center, Anna Meyer Children's Hospital, Florence, Italy;7. Center of Pediatric Diabetology, University of Chieti, Chieti, Italy;8. Department of Pediatrics, University of Messina, Messina, Italy;9. Institute of Endocrinology, Sheba Medical Center, Ramat Gan, Israel
Abstract:Abstract: Sensor‐augmented pumps, which consist of a pump and a continuous glucose monitoring system, offer considerable therapeutic opportunities, despite requiring close attention in the early phase of their use. The aim of this paper is to provide recommendations on the use of a predictive low glucose management (PLGM) system (Minimed 640G?, Medtronic, Northridge, CA, USA) in adolescents with type 1 diabetes either at the start of therapy or during follow‐up. Sound clinical recommendations on PLGM are of increasing importance since several recent papers have reported significant clinical improvements in patients with PLGM, especially in adults. These recommendations are based on the experience of a group of pediatric endocrinologists who collaborated to closely and intensively study the on‐boarding of adolescent patients with type 1 diabetes on automated systems to gain first‐hand experience and peer‐to‐peer insights in a unique free‐living environment. The suggestions provided here are indicative, so can be adapted to the individual realities and experiences of different diabetes centers. However, we believe that close adherence to the proposed scheme is likely to increase the chances of improving the clinical and metabolic outcomes of patients treated with this therapy.
Keywords:continuous glucose monitoring  continuous subcutaneous insulin infusion  insulin pump therapy  predictive low‐glucose suspend  recommendations     predictive low‐glucose management        sensor augmented pump   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号