首页 | 本学科首页   官方微博 | 高级检索  
     


Reliability and failure modes of narrow implant systems
Authors:Ronaldo Hirata  Estevam A. Bonfante  Rodolfo B. Anchieta  Lucas S. Machado  Gileade Freitas  Vinicius P. Fardin  Nick Tovar  Paulo G. Coelho
Affiliation:1.Department of Biomaterials and Biomimetics,New York University College of Dentistry,New York,USA;2.Department of Prosthodontics, Bauru College of Dentistry,University of S?o Paulo,Bauru,Brazil;3.Universidade do Norte Paulista—UNORP,S?o José do Rio Preto,Brazil;4.Department of Operative Dentistry,S?o Paulo State University,Ara?atuba,Brazil;5.Department of Dental Surgery and Traumatology, Ribeir?o Preto School of Dentistry,University of S?o Paulo,Ribeir?o Preto,Brazil;6.Department of Periodontology and Implant Dentistry,New York University College of Dentistry,New York,USA;7.Division of Engineering,New York University Abu Dhabi,Abu Dhabi,United Arab Emirates
Abstract:

Objectives

Narrow implants are indicated in areas of limited bone width or when grafting is nonviable. However, the reduction of implant diameter may compromise their performance. This study evaluated the reliability of several narrow implant systems under fatigue, after restored with single-unit crowns.

Materials and methods

Narrow implant systems were divided (n = 18 each), as follows: Astra (ASC); BioHorizons (BSC); Straumann Roxolid (SNC), Intra-Lock (IMC), and Intra-Lock one-piece abutment (ILO). Maxillary central incisor crowns were cemented and subjected to step-stress accelerated life testing in water. Use level probability Weibull curves and reliability for a mission of 100,000 cycles at 130- and 180-N loads (90 % two-sided confidence intervals) were calculated. Scanning electron microscopy was used for fractography.

Results

Reliability for 100,000 cycles at 130 N was ~99 % in group ASC, ~99 % in BSC, ~96 % in SNC, ~99 % in IMC, and ~100 % in ILO. At 180 N, reliability of ~34 % resulted for the ASC group, ~91 % for BSC, ~53 % for SNC, ~70 % for IMC, and ~99 % for ILO. Abutment screw fracture was the main failure mode for all groups.

Conclusions

Reliability was not different between systems for 100,000 cycles at the 130-N load. A significant decrease was observed at the 180-N load for ASC, SNC, and IMC, whereas it was maintained for BSC and ILO.

Clinical relevance

The investigated narrow implants presented mechanical performance under fatigue that suggests their safe use as single crowns in the anterior region.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号