首页 | 本学科首页   官方微博 | 高级检索  
检索        


Safety and Effectiveness of Transhepatic Access for Percutaneous Renal Mass Cryoablation: A Multicenter Cohort
Institution:1. Department of Vascular and Interventional Radiology, ChristianaCare, Newark, Delaware;2. Division of Interventional Radiology, University of Alabama Medical Center, Birmingham, Alabama;3. Division of Abdominal Imaging, Department of Radiology, Mayo Clinic, Rochester, Minnesota
Abstract:PurposeTo establish transhepatic percutaneous cryoablation of renal masses as a safe and effective approach.Materials and MethodsA retrospective review of records from 3 separate medical centers was performed identifying 23 patients (median age, 63 years range 41–84 years]; 12 female 52.2%]) who underwent percutaneous transhepatic cryoablation for right-sided renal masses (median diameter, 2.4 cm 1.5–4.6 cm]) between 2008 and 2021. The median radius, exophytic/endophytic, nearness to collecting system or sinus, anterior/posterior, and location relative to polar lines (RENAL) nephrometry score was 5 (4–10). Adverse events (AEs) were classified according to the Society of Interventional Radiology (SIR) and Clavien-Dindo (CD) classifications. Primary and secondary technical success of each procedure were recorded.ResultsRenal cell carcinoma (of any subtype) was found in 10 (71.5%) of the 14 masses that were biopsied. Tract cautery was used for transhepatic probes in 14 (63.6%) of 22 procedures. Three (13%) of 23 patients had postprocedural AEs. Two cases (8.6%) were hemorrhages related to transhepatic access (SIR moderate-2, CD 2; SIR severe-3, CD 1), and 1 case (4.4%) was related to bowel injury (SIR severe-3, CD 3a). There were no instances of pneumothorax. Tract cautery was used in the procedures that resulted in an AE. Primary technical success was achieved in 84.2% (16/19) of procedures, whereas secondary technical success was achieved in 2 additional patients. The secondary technical success rate was 94.7% (18/19). Four patients did not have imaging follow-up.ConclusionsThe transhepatic approach to cryoablation of renal masses appears to have an acceptable safety profile and technical success rate. Larger studies, preferably comparative to nontranshepatic approach, are recommended.
Keywords:AE"}  {"#name":"keyword"  "$":{"id":"kwrd0015"}  "$$":[{"#name":"text"  "_":"adverse event  CT"}  {"#name":"keyword"  "$":{"id":"kwrd0025"}  "$$":[{"#name":"text"  "_":"computed tomography  POD"}  {"#name":"keyword"  "$":{"id":"kwrd0035"}  "$$":[{"#name":"text"  "_":"postoperative day  RENAL"}  {"#name":"keyword"  "$":{"id":"kwrd0045"}  "$$":[{"#name":"text"  "_":"radius  exophytic/endophytic  nearness to collecting system or sinus  anterior/posterior  and location relative to polar lines  RF"}  {"#name":"keyword"  "$":{"id":"kwrd0055"}  "$$":[{"#name":"text"  "_":"radiofrequency  US"}  {"#name":"keyword"  "$":{"id":"kwrd0065"}  "$$":[{"#name":"text"  "_":"ultrasound
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号