首页 | 本学科首页   官方微博 | 高级检索  
检索        


Long-term relation between deltoid muscle volume and clinical outcomes in a reverse shoulder arthroplasty
Institution:1. Department Orthopaedic Surgery, Reinier Haga Orthopedic Centre, Zoetermeer, The Netherlands;2. Department Radiology, Haga Hospital, The Hague, The Netherlands;3. Department Orthopaedic Surgery, Bergman Clinics, Rijswijk, The Netherlands;1. Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, MA, USA;2. Boston Sports and Shoulder Center, Waltham, MA, USA;3. MedStar Union Memorial Hospital, Baltimore, MD, USA;1. Orthopaedics Biomechanics Laboratory, Sunnybrook Research Institute, Toronto, Ontario, Canada;2. Division of Orthopaedic Surgery, University of Toronto, Toronto, Ontario, Canada;3. Division of Orthopaedic Surgery, Sunnybrook Health Sciences Centre, Ontario, Canada;4. Division of Orthopaedics, Department of Surgery, University of Toronto, Toronto, Ontario, Canada;5. Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada;1. Department of Orthopaedic Surgery, Rutgers New Jersey Medical School, Newark, NJ, USA;2. Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France;1. Avicenne Teaching Hospital, Assistance Publique-Hopitaux de Paris, Bobigny, France;2. Université Sorbonne-Paris-Nord, Campus de Bobigny, Paris, France;3. Imperial College, St Mary''s Hospital Campus, Queen Elizabeth Queen Mother Building, London, United Kingdom;4. Université Sorbonne-Paris-Nord, Equip Projet MOVEO, La MSN, Saint-Denis, Paris, France
Abstract:BackgroundDeltoid muscle function is important in reverse shoulder arthroplasty (RSA). Concerns are raised on the resistance of the deltoid muscle against the postoperative distalization. We hypothesize that a decreased volume of the deltoid muscle is related to worse clinical outcomes after a long-term follow-up. An observational study was conducted to evaluate the relation between volume of the deltoid muscle and clinical outcomes after a long-term follow-up on RSA.MethodsEligible for inclusion was patients who underwent RSA for cuff arthropathy after minimum 3 years follow-up. Fifty-nine patients were enrolled in this study. Preoperative volume was measured on magnetic resonance imaging or computed tomography. Postoperative deltoid volume was evaluated on ultrasonography. Distalization of the humerus was measured on radiographs. Clinical outcomes were measured by the Constant-Murley Score (CMS), Oxford Shoulder Score, and range of motion. Multivariable linear regression models were used to examine the association between the deltoid volume and clinical outcomes, and between distalization and deltoid volume or clinical outcomes.ResultsThe mean follow-up period was 88.7 ± 29.1 months. Postoperative deltoid volume positively correlated with both CMS (P = .045) and abduction strength, in both operated (P = .01) and contralateral side (P < .001). No association between deltoid volume and Oxford Shoulder Score or range of motion, and no association between preoperative volume and postoperative CMS was found. The mean distalization of the humerus was 21.2 mm 95% CI: 19.4-22.9 mm]. Distalization negatively correlated with deltoid volume (P = .012) and CMS (P = .009).ConclusionsPostoperative deltoid volume correlated with clinical outcomes as measured by CMS and abduction strength after a long-term follow-up on RSA.
Keywords:Reverse shoulder arthroplasty  Deltoid muscle volume  Clinical outcome  Range of motion  Distalization
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号