首页 | 本学科首页   官方微博 | 高级检索  
     

高效液相色谱法测定丹参酮滴耳液中4种丹参酮成分含量
引用本文:刘刚,张启明,张捷,高文娟,常华,谭生建. 高效液相色谱法测定丹参酮滴耳液中4种丹参酮成分含量[J]. 中国药学杂志, 2004, 39(3): 218-220
作者姓名:刘刚  张启明  张捷  高文娟  常华  谭生建
作者单位:1. 解放军第306医院药剂科,北京100101
2. 中国药品生物制品检定所,北京,100050
摘    要: 目的 利用梯度洗脱,建立高效液相色谱测定丹参酮滴耳液中二氢丹参酮Ⅰ、隐丹参酮、丹参酮Ⅰ和丹参酮ⅡA含量的方法。方法 采用高效液相色谱法。Intersil C18分析色谱柱(4.6 mm×250 mm,5 μm),流动相为乙腈-10%乙腈梯度洗脱,流速1.6 mL·min-1,检测波长254 nm。结果 二氢丹参酮Ⅰ、隐丹参酮、丹参酮Ⅰ和丹参酮ⅡA保留时间分别为11.9,19.2,21.3和28.5 min,与各自相邻峰的分离度均大于1.5,理论板数分别为3?310,4 278,3 624和20 677。二氢丹参酮Ⅰ平均回收率为101.3%,RSD=2.2%,隐丹参酮平均回收率为97.2%,RSD=2.2%,丹参酮Ⅰ平均回收率为102.1%,RSD=3.0%,丹参酮ⅡA平均回收率为99.5%,RSD=1.9%。二氢丹参酮Ⅰ、隐丹参酮、丹参酮Ⅰ和丹参酮ⅡA最低检出浓度分别约为0.6,0.9,0.6和0.3 μg·mL-1。结论 本法操作简便,测定结果准确可靠,可用于丹参酮滴耳液中二氢丹参酮Ⅰ、隐丹参酮、丹参酮Ⅰ和丹参酮ⅡA的含量测定。

关 键 词:高效液相色谱法  丹参酮滴耳液  二氢丹参酮Ⅰ  隐丹参酮  丹参酮工Ⅰ  丹参酮ⅡA
文章编号:1001-2494(2004)03-0218-03
收稿时间:2002-12-20;

Determination of dihydrotanshinone Ⅰ,cryptotanshinone,tanshinone Ⅰ and tanshinone Ⅱ A in tanshinone ear drops by HPLC
LIU Gang ,ZHANG Qi-ming ,ZHANG Jie ,GAO Wen-juan ,CHANG Hua ,TAN Sheng-jian. Determination of dihydrotanshinone Ⅰ,cryptotanshinone,tanshinone Ⅰ and tanshinone Ⅱ A in tanshinone ear drops by HPLC[J]. Chinese Pharmaceutical Journal, 2004, 39(3): 218-220
Authors:LIU Gang   ZHANG Qi-ming   ZHANG Jie   GAO Wen-juan   CHANG Hua   TAN Sheng-jian
Affiliation:LIU Gang 1,ZHANG Qi-ming 2,ZHANG Jie 1,GAO Wen-juan 1,CHANG Hua 1,TAN Sheng-jian 1
Abstract:OBJECTIVE A quantitative method was developed for the determination of dihydrotanshinone Ⅰ, cryptotanshinone, tanshinone Ⅰ and tanshinone ⅡA in tanshinone ear drops by HPLC METHODS Column Intersil C18 was used. The mobile phase was composed of acetonitrile - 10% acetonitrile with gradient eluation. The flow rate was 1.6 mL·min-1 with the wavelength at 254 nm RESULTS The number of theoretical plates calculated by dihydrotanshinone Ⅰ, cryptotanshinone, tanshinoneⅠand tanshinoneⅡA peak were 3 310, 4?278, 3 624 and 20 677 respectively. The average recoveries of dihydrotanshinone Ⅰ, cryptotanshinone, tanshinoneⅠ, tanshinone ⅡA were 101.3% (RSD=2.2%), 97.2% (RSD=2.2%), 102.1% (RSD=3.0%) and 99.5% (RSD=1.9%) respectively. The detection limits of dihydrotanshinone Ⅰ, cryptotanshinone, tanshinone Ⅰ and tanshinone ⅡA were about 0.6, 0.9, 0.6 and 0.3 μg·mL-1 respectively CONCLUSION The method was sensitive, rapid and accurate.
Keywords:HPIC  tanshinone ear drops  dihydrotanshinone I  cryptotanshinone  tanshinon  tanshinone
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国药学杂志》浏览原始摘要信息
点击此处可从《中国药学杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号