首页 | 本学科首页   官方微博 | 高级检索  
     


Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic fixed partial dentures. Part III: Marginal and internal fit
Authors:Goran I. Benic  Irena Sailer  Marco Zeltner  Janine N. Gütermann  Mutlu Özcan  Sven Mühlemann
Affiliation:1. Senior Teaching and Research Assistant, Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland;2. Professor, Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland;3. Senior Teaching and Research Assistant, Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland;4. Master of Dental Medicine, Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland;5. Professor, Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland;6. Senior Teaching and Research Assistant, Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
Abstract:

Statement of problem

Trials comparing the overall performances of digital and conventional workflows in restorative dentistry are lacking.

Purpose

The purpose of the third part of this clinical study was to test whether the fit of zirconia 3-unit frameworks for fixed partial dentures fabricated with fully digital workflows differed from that of metal frameworks fabricated with the conventional workflow.

Material and methods

In each of 10 participants, 4 fixed-partial-denture frameworks were fabricated for the same abutment teeth according to a randomly generated sequence. Digital workflows were applied for the fabrication of 3 zirconia frameworks with Lava, iTero, and Cerec infiniDent systems. The conventional workflow included a polyether impression, manual waxing, the lost-wax technique, and the casting of a metal framework. The discrepancies between the frameworks and the abutment teeth were registered using the replica technique with polyvinyl siloxane. The dimensions of the marginal discrepancy (Discrepancymarginal) and the internal discrepancy in 4 different regions of interest (Discrepancyshoulder, Discrepancyaxial, Discrepancycusp, and Discrepancyocclusal) were assessed using a light microscope. Post hoc t tests with Bonferroni correction were applied to detect differences (α=.05).

Results

Discrepancyshoulder was 96.1 ±61.7 μm for the iTero, 106.9 ±96.0 μm for the Lava, 112.2 ±76.7 μm for the Cerec infiniDent, and 126.5 ±91.0 μm for the conventional workflow. The difference between the iTero and the conventional workflow was statistically significant (P=.029). Discrepancyocclusal was 153.5 ±66.8 μm for the iTero, 203.3 ±127.9 μm for the Lava, 179.7 ±63.1 μm for the Cerec infiniDent, and 148.8 ±66.8 μm for the conventional workflow. Discrepancyocclusal was significantly lower for the conventional workflow than for the Lava and the Cerec infindent workflows (P<.01). The iTero resulted in significantly lower values of Discrepancyocclusal than the Lava and the Cerec infiniDent workflows (P<.01).

Conclusions

In terms of framework fit in the region of the shoulder, digitally fabricated zirconia 3-unit frameworks presented similar or better fit than the conventionally fabricated metal frameworks. In the occlusal regions, the conventionally fabricated metal frameworks achieved a more favorable fit than the CAD-CAM zirconia frameworks.
Keywords:Corresponding author: Dr Goran I. Benic   Clinic of Fixed and Removable Prosthodontics and Dental Material Science   Center of Dental Medicine   University of Zurich   Plattenstrasse 11   Zurich CH-8032   SWITZERLAND
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号