首页 | 本学科首页   官方微博 | 高级检索  
检索        

声辐射力脉冲成像技术定量评价兔肝缺血后弹性改变的实验研究
引用本文:王力,黄品同,何慧疗,孔凡雷,陆兆龄,郑枝兰,王宗敏,吴红芳,李哲群.声辐射力脉冲成像技术定量评价兔肝缺血后弹性改变的实验研究[J].中华超声影像学杂志,2010,19(11).
作者姓名:王力  黄品同  何慧疗  孔凡雷  陆兆龄  郑枝兰  王宗敏  吴红芳  李哲群
作者单位:1. 浙江省人民医院超声科,杭州,310014
2. 浙江大学医学院附属第二医院超声科
3. 温州医学院附属第二医院超声科,325027
4. 北京和睦家医院
5. 温州医学院附属第二医院病理科,325027
6. 温州医学院附屑第一医院脑外科
摘    要:目的 运用声辐射力脉冲成像(acoustic radiation force impulse,ARFI)技术评价兔肝门脉主干及肝固有动脉同时阻断后的弹性改变.方法 通过同时阻断肝门脉及肝固有动脉的方法建立兔肝缺血模型,运用ARFI技术分别于肝缺血前(T0)及缺血后5 min(T1)、20 min(T2)、30 min(T3)对兔右肝同一部位进行检查,测量肝缺血过程中肝组织的弹性;在相应时间点测定血清门冬氨酸氨基转移酶(AST)、丙氨酸氨基转移酶(ALT)水平,以及肝穿刺活检;最后进行统计分析.结果 T2兔右肝ARFI测值即组织剪切波速度(Vs)明显高于T0,差异有统计学意义(P<0.05),T3兔右肝Vs明显高于T2,差异有统计学意义(P<0.05);T2血清AST、ALT水平稍高于T0,但差异无统计学意义(P>0.05),T3血清AST、ALT水平明显高于T2,差异有统计学意义(P<0.05);组织学观察在T2、T3可见兔肝缺血损伤病理改变.结论 ARFI技术定量分析缺血肝组织弹性改变能在较早期准确、客观地反映肝缺血损伤的严重程度.

关 键 词:超声检查  肝疾病  缺血  弹性  声辐射力脉冲成像

Quantitative assessment of ischemic liver's elastic changes in rabbits using acoustic radiation force impulse (ARFI)
WANG Li,HUANG Pin-tong,HE Hui-liao,KONG Fan-lei,LU Zhao-ling,ZHENG ZHi-lan,WANG Zong-min,WU Hong-fang,LI Zhe-qun.Quantitative assessment of ischemic liver's elastic changes in rabbits using acoustic radiation force impulse (ARFI)[J].Chinese Journal of Ultrasonography,2010,19(11).
Authors:WANG Li  HUANG Pin-tong  HE Hui-liao  KONG Fan-lei  LU Zhao-ling  ZHENG ZHi-lan  WANG Zong-min  WU Hong-fang  LI Zhe-qun
Abstract:Objective To evaluate the change of elasticity of rabbit liver following portal inflow vessels occlusion using acoustic radiation force impulse (ARFI). Methods Twelve Japanese white big ear rabbits were used to establish total hepatic vascular exclusion animal models by occluding the portal inflow vessels. The elasticity of rabbits' right liver was detected during the stages of baseline(T0), 5 min(T1),20min(T2) ,30min (T3)after occluding the portal inflow vessels using ARFI respectively. The elasticity of rabbit liver, levels of serum's aspartate aminotransferase (AST), alanine aminotransferase (ALT) and historical results of hepatic tissue during different stage were compared. Results Shear wave velocity(Vs)of rabbits' right livers in T2 was significantly higher than that in T0 ( P <0.05) and Vs of rabbits' right livers in T3 was significantly higher than that in T2 ( P <0.05). No significant differences of serum's AST,ALT levels between T2 and T0 were found,while the Vs of rabbit live in T2 was slightly higher than that in T0 (P>0.05), serum's AST, ALT levels in T3 were significantly higher than that in T2 ( P <0.05).Historical changes of liver ischemia and injury were observed in T2 and T3 with light microscopy. Conclusions The liver ischemia and injury severity can be accurately and objectively evaluated using ARFI.
Keywords:Ultrasonography  Liver diseases  Ichemia  Elasticity  Acoustic radiation force impulse
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号