首页 | 本学科首页   官方微博 | 高级检索  
检索        


The significance of repeat testing in Turkish blood donors screened with HBV,HCV and HIV immunoassays and the importance of S/CO ratios in the interpretation of HCV/HIV screening test results and as a determinant for further confirmatory testing
Authors:Ali Acar  Sabri Kemahli  Husnu Altunay  Erdogan Kosan  Oral Oncul  Levent Gorenek  Saban Cavuslu
Institution:1. Department of Infectious Disease and Clinical Microbiology, Gulhane Military Medical Academy, Haydarpasa Training Hospital, Uskudar, Istanbul;2. Department of Paediatrics (Ped. Haematology), Faculty of Medicine, Ankara University, Ankara;3. Capa Red Crescent Centre, Istanbul, Turkey
Abstract:The purpose of this study was to investigate the intra‐assay correlations amongst initial reactive and repeat screening results used in enzyme immunoassays (EIAs) for hepatitis B virus (HBV), hepatitis C virus (HCV) and HIV in blood donors. This study evaluated the value of using the power of the signal to cut‐off (S/CO) ratio index for confirming anti‐HCV/HIV reactive screening results, thereby touching upon the utility of S/CO indices in determining whether further confirmatory testing was necessary. Screening test results of the 72 695 blood donors were evaluated over a 1‐year period. Correlation analysis among each initial test and retests was done by Pearson r test. Appropriate S/CO values to determine the need of the confirmation testing was investigated by ROC analyses. EIA intra‐assay correlations were of statistical significance and were determined as follows: 0·948 for anti‐HCV, 0·827 for anti‐HIV and 0·948 for HBsAg. The threshold S/CO ratio values which predicted more than 95% of the confirmation test result were 3·8 for HCV and 5·6 for HIV. We were able to demonstrate a strong level of intra‐assay correlation amongst EIAs, thereby eliminating the need for repetition of the screening test. Hence, we suggest that repeat screening should only be limited to HBV and HIV tests with low EIA S/CO ratios. Thus, using the power of the S/CO ratio in determining the need for HCV confirmation testing can be a cost‐effective measure, especially if the S/CO value is ≥3·8.
Keywords:blood donors  HBV  HCV  HIV  screening tests
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号