首页 | 本学科首页   官方微博 | 高级检索  
     


Fetal heart rate after vibroacoustic stimulation
Authors:Jeong Kyu Hoh  Kyung-Joon Cha  Moon-Il Park
Affiliation:a Department of Obstetrics and Gynecology, School of Medicine, University of California, Irvine, CA, USA
b Department of Mathematics, College of Natural Science, Hanyang University, Seoul, Korea
c Department of Obstetrics and Gynecology, College of Medicine, Hanyang University, Seoul, Korea
d Research Institute of Natural Sciences, Hanyang University, Seoul, Korea
Abstract:

Objective

To define reference ranges for fetal heart rate (FHR) parameters after vibroacoustic stimulation (VAS) according to gestational age by determining the relationship between FHR and gestational age using a computerized analysis system.

Methods

Data were analyzed from 3453 women using 10-minute observational recordings during nonstress testing (NST) and VAS testing. FHR parameters were analyzed according to gestational age.

Results

All FHR parameters were related to gestational age except for mean baseline FHR, which did not vary significantly with gestational age. All other parameters followed trends similar to the NST results, except for decelerations.

Conclusion

FHR parameters after VAS differed significantly according to gestational age. The results suggest that the gestational age of the fetus should be considered when interpreting FHR patterns after VAS.
Keywords:Computerized analysis   Fetal heart rate parameters   Gestational age   Vibroacoustic stimulation