首页 | 本学科首页   官方微博 | 高级检索  
检索        


Heparin-Coated Cardiopulmonary Bypass Circuit: Clinical Effects in Pediatric Cardiac Surgery
Authors:Kagami Miyaji  MD    Robert L Hannan  MD    Jorge Ojito  BS CCP    Jeffery P Jacobs  MD    Jeffrey A White  MS  Redmond P Burke  MD
Institution:Department of Cardiovascular Surgery, Miami Children's Hospital, Florida, USA. kagami111@aol.com
Abstract:OBJECTIVES: Heparin-coated cardiopulmonary bypass (CPB) circuits have been reported to reduce complement activation and the inflammatory response associated with CPB. We retrospectively compared patients utilizing heparin-coated perfusion circuits with those using noncoated circuits to determine the clinical effects of the different circuits in pediatric cardiac surgery. METHODS: Between July 1995 and July 1997, 203 patients weighing < 10 kg underwent cardiac surgery, 153 patients using heparin-coated bypass circuits and 50 patients using noncoated circuits. The 50 patients operated on with the noncoated circuit (Group N) were matched to 100 patients operated on with coated circuits (Group H) in age, weight, and type of procedure. Urine output during bypass, blood products used after bypass, postoperative ventilation days, hospital stay, morbidity, and mortality were compared between these groups. RESULTS: Body weight, perfusion time, and procedure time were not different between the two groups. Urine output during bypass was notably greater in Group H than in Group N (11.3 +/- 10.5 mL/kg per hour vs 4.8 +/- 3.1 mL/kg per hour, respectively, p < 0.0001). Postoperative mechanical ventilation markedly decreased in Group H (Group H vs N = 2.8 +/- 2.7 days vs 5.1 +/- 7.5 days, respectively, p < 0.05). Red blood cell usage, hospital stay, morbidity, and mortality were not statistically different, although there was a tendency toward decreased transfusion of red cell and platelets in Group H (Group H vs N = 61.2 +/- 121.1 mL/kg vs 102.0 +/- 176.7 mL/kg, respectively, in red cell, p = 0.15; and Group H vs N = 7.9 +/- 13.7 mL/kg vs 13.2 +/- 24.5 mL/kg, respectively, in platelets, p = 0.16). CONCLUSIONS: Patients operated on with the use of heparin-coated circuits had increased urine output during bypass and required less time postoperatively on the ventilator. These results suggest a reduction in the acute inflammatory response, capillary leakage, and overall systemic edema. We now routinely use coated circuits on all pediatric pump cases.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号