首页 | 本学科首页   官方微博 | 高级检索  
检索        


Correlation and Agreement of Yttrium-90 Positron Emission Tomography/Computed Tomography with Ex Vivo Radioembolization Microsphere Deposition in the Rabbit VX2 Liver Tumor Model
Authors:Andrew C Gordon  Vanessa L Gates  Sarah B White  Kathleen R Harris  Daniel Procissi  Zhuoli Zhang  Weiguo Li  Donald Samaan  Jodi R Nicolai  Samdeep K Mouli  Kent T Sato  Robert K Ryu  Reed A Omary  Riad Salem  Robert J Lewandowski  Andrew C Larson
Institution:1. Department of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois;2. Department of Medicine, Hematology/Oncology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois;3. Department of Surgery, Organ Transplantation, Northwestern University, Feinberg School of Medicine, Chicago, Illinois;4. Department of Biomedical Engineering, Northwestern University, Evanston, Illinois;5. Department of Radiology, Division of Vascular & Interventional Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin;6. Medical Health Physics, Stanford University, Palo Alto, California;7. Department of Radiology, University of Colorado, Aurora, Colorado;8. Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
Abstract:PurposeTo demonstrate a stronger correlation and agreement of yttrium-90 (90Y) positron emission tomography (PET)/computed tomography (CT) measurements with explant liver tumor dosing compared with the standard model (SM) for radioembolization.Materials and MethodsHepatic VX2 tumors were implanted into New Zealand white rabbits, with growth confirmed by 7 T magnetic resonance imaging. Seventeen VX2 rabbits provided 33 analyzed tumors. Treatment volumes were calculated from manually drawn volumes of interest (VOI) with three-dimensional surface renderings. Radioembolization was performed with glass 90Y microspheres. PET/CT imaging was completed with scatter and attenuation correction. Three-dimensional ellipsoid VOI were drawn to encompass tumors on fused images. Tumors and livers were then explanted for inductively coupled plasma (ICP)-optical emission spectroscopy (OES) analysis of microsphere content. 90Y PET/CT and SM measurements were compared with reference standard ICP-OES measurements of tumor dosing with Pearson correlation and Bland-Altman analyses for agreement testing with and without adjustment for tumor necrosis.ResultsThe median infused activity was 33.3 MBq (range, 5.9–152.9). Tumor dose was significantly correlated with 90Y PET/CT measurements (r = 0.903, P < .001) and SM estimates (r = 0.607, P < .001). Bland-Altman analyses showed that the SM tended to underestimate the tumor dosing by a mean of ?8.5 Gy (CI, ?26.3–9.3), and the degree of underestimation increased to a mean of ?18.3 Gy (CI, ?38.5–1.9) after the adjustment for tumor necrosis.Conclusions90Y PET/CT estimates were strongly correlated and had better agreement with reference measurements of tumor dosing than SM estimates.
Keywords:ARRIVE"}  {"#name":"keyword"  "$":{"id":"kwrd0015"}  "$$":[{"#name":"text"  "_":"animal research: reporting in vivo experiments  CI"}  {"#name":"keyword"  "$":{"id":"kwrd0025"}  "$$":[{"#name":"text"  "_":"confidence interval  DVH"}  {"#name":"keyword"  "$":{"id":"kwrd0035"}  "$$":[{"#name":"text"  "_":"dose-volume histogram  HCC"}  {"#name":"keyword"  "$":{"id":"kwrd0045"}  "$$":[{"#name":"text"  "_":"hepatocellular carcinoma  ICP-OES"}  {"#name":"keyword"  "$":{"id":"kwrd0055"}  "$$":[{"#name":"text"  "_":"inductively coupled plasma optical emission spectroscopy  LDM"}  {"#name":"keyword"  "$":{"id":"kwrd0065"}  "$$":[{"#name":"text"  "_":"local deposition method  MIRD"}  {"#name":"keyword"  "$":{"id":"kwrd0075"}  "$$":[{"#name":"text"  "_":"medical internal radiation dose  NHP"}  {"#name":"keyword"  "$":{"id":"kwrd0085"}  "$$":[{"#name":"text"  "_":"normal hepatic parenchyma  SM"}  {"#name":"keyword"  "$":{"id":"kwrd0095"}  "$$":[{"#name":"text"  "_":"standard model  T2w"}  {"#name":"keyword"  "$":{"id":"kwrd0105"}  "$$":[{"#name":"text"  "_":"T2-weighted  T:N"}  {"#name":"keyword"  "$":{"id":"kwrd0115"}  "$$":[{"#name":"text"  "_":"tumor:normal ratio  TSE"}  {"#name":"keyword"  "$":{"id":"kwrd0125"}  "$$":[{"#name":"text"  "_":"turbo spin echo  VOI"}  {"#name":"keyword"  "$":{"id":"kwrd0135"}  "$$":[{"#name":"text"  "_":"volume of interest  yttrium-90 positron emission tomography/computed tomography
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏