Interactions Between Transvenous Nonthoracotomy Cardioverter Defibrillator Systems and Permanent Transvenous Endocardial Pacemakers
Authors:MARY J GEIGER  PADRAIG O'NEILL  ARJUN SHARMA  ANNE SKADSEN  LEANDRO ZIMERMAN  RUTH ANN GREENFIELD  KEITH H NEWBY  J MARCUS WHARTON  VIRGINIA KENT  REA NATALE
Institution:Department of Cardiology, Duke University Medical Center and the Durham Veterans Administration Medical Center, Durham, North Carolina;University of California at Davis, Sacramento, California
Abstract:Limited information is available regardIng potential adverse Interactions between transvenous nonthoracotomy cardioverter defibrillators and pacemakers. We describe our experience with 37 patients who have undergone successful Implantation of both a transvenous defibrillator and pacemaker. The patients’mean age was 64 ± 12,9 years. Thirty-three were male and four were female. The mean LVEF wos 30.8%±11.8%, The indications for pacemaker implantation included sick sinus syndrome in 13 patients, complete heart block in 15 patients, sinus brady-cardia secondary to medications In 8 patients, and neurocardlogenlc syncope In 1 patient. The Indications for Insertion of a defibrillator Included medically refractory VT in 27 patients and sudden cardiac death in 10 patients. Twenty-three patients received an Endotak lead and 14 patients received o Transvene lead. Eighteen patients had a pacemaker prior to an ICD, 14 patients had an ICD prior to a pacemaker, and 4 patients had both devices placed simultaneously. Interaction was evaluated at Implant of the second device and 1–3 days after both devices were placed. Detection of VF/VT was analyzed during asynchronous pacing (DOO/VOO) with maximum pacing output. In addition, in six patients, DFT was determined before and after pacemaker implantation. In 14 patients (38%), device interactions that could not always be optimally corrected were observed. In five patients, the pacemaker was reset to the “noise reversion” mode after high energy ICD discharge, Oversensing of atrial pacemaker stimuli resulted in inappropriate ICD firings in four patients. This wos observed only with a specific device ond could not be prevented by atriol leod repositioning in two of them, but required reprogramming of the pacemaker to the VVImode. An increase in DFT was observed in five patients who had a pacemaker implanted after on ICD. Compared with previously published studies, a greater frequency of tronsvenous ICD and pacemaker Interactions were observed. Considering that almost 50% of the patients already have o pacemaker ot the time of ICD Implant, the ovalloblllty of deflbrlllotors with dual chamber pocing capability will not eliminate the potential for this problem.
Keywords:transvenous defibrillator  pacemaker  malfunction
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号