首页 | 本学科首页   官方微博 | 高级检索  
     

视网膜脱离巩膜环扎术后眼球生物测量及屈光状态观察
引用本文:林季建,李棣,陈友慈. 视网膜脱离巩膜环扎术后眼球生物测量及屈光状态观察[J]. 中华眼底病杂志, 1999, 15(4): 227-229
作者姓名:林季建  李棣  陈友慈
作者单位:浙江大学医学院附属第二医院眼科中心(林季建),杭州市第一人民医院眼科(李棣!310006,陈友慈!310006,董映!310006,胡勇平!310006)
摘    要:目的 研究视网膜脱离巩膜环扎术后眼部屈光状态的改变及其影响因素。 方法 用眼科超声仪、角膜曲率仪、验光仪等对巩膜环扎加压眼内嵴高为4~6 D的86例原发性视网膜脱离患者的86只患眼手术前1天及术后第1,4,12周时前房深度、眼轴长度、晶状体厚度、眼屈光度、角膜曲率等进行测量并将结果进行比较。 结果 前房深度在术后第1,4,12周时较术前显著变浅(P<0.05);眼轴长度无明显变化;晶状体厚度和眼屈光度在术后第1,4周时较术前分别有增厚和向负值偏移(P<0.05),术后第12周时两者与术前比较无显著差异;巩膜环扎联合≤1象限加压块组术后第1,4周加压径线的角膜曲率与术前比较差异显著(P<0.05)。 结论 在较高眼内环扎嵴时,术眼术后早期晶状体增厚和前房变浅是眼屈光度负值增加的主要因素,其原因与术后虹膜晶状体隔移位等有关。 (中华眼底病杂志, 1999, 15: 227-229)

关 键 词:视网膜脱离 巩膜扣带术 屈光不正 屈光计检查
收稿时间:1999-01-25
修稿时间:1999-05-24

Refractive changes of ocular measurable factors after scleral buckling surgery
LIN Ji-jian,LI Di,CHEN You-ci,et al. Refractive changes of ocular measurable factors after scleral buckling surgery[J]. Chinese Journal of Ocular Fundus Diseases, 1999, 15(4): 227-229
Authors:LIN Ji-jian  LI Di  CHEN You-ci  et al
Affiliation:Department of Ophthalmology,Hangzhou First Hospital,Hangzhou 310006,China
Abstract:Objective To investigate the refractive changes of ocular measurable factors due to scleral buckling surgery. Methods A total of 86 eyes of successful rhegmatogenous retinal detachment with a higher encircling scleral buckle underwent A-scan and keratometer examination before surgery as well as l week,4 and 12 weeks after surgery.The refractive factors included the depth of anterior chamber,thickness of lens,axial length of eye,corneal curvature and refraction of eye were detected pre- and post-operatively. Results Compared with preoperation,the depth of anterior chamber was decreased significantly at the lst,4th and 12th postoperative week(P<0.05),while no significant change of the axial length of eye was observed.The thickness of lens was increased significantly and the refractive error was myopic shifted at the lst and 4th week after operation(P<0.05),but no significant change was observed at the 12th postoperative week.Statistically significant difference was also observed in corneal curvature of central axis in the local buckle≤1 quadrant with encircling group between preoperation and the lst and 4th postoperative week. Conclusions With higher encircling scleral buckle,the refractive change after buckling surgery may be caused primarily by the shallowing of anterior chamber and thickening of lens. (Chin J Ocul Fundus Dis, 1999, 15: 227-229)
Keywords:Retinal detachment/surgery Scleral buckling/adverse effects Refractive errors/etiology Refractometry
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《中华眼底病杂志》浏览原始摘要信息
点击此处可从《中华眼底病杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号