首页 | 本学科首页   官方微博 | 高级检索  
检索        

CT引导辅助3D打印个体化非共面模板指导125I粒子治疗盆腔复发肿瘤剂量学研究
引用本文:姜玉良,王皓,吉喆,郭福新,孙海涛,范京红,张路静,田素青,王俊杰.CT引导辅助3D打印个体化非共面模板指导125I粒子治疗盆腔复发肿瘤剂量学研究[J].中华放射肿瘤学杂志,2016,25(9):959-964.
作者姓名:姜玉良  王皓  吉喆  郭福新  孙海涛  范京红  张路静  田素青  王俊杰
作者单位:100191 北京大学第三医院肿瘤放疗科
基金项目:首都临床特色应用研究重点项目(Z151100004015171),国家自然科学基金青年基金项目(81402519) Beijing Municipal Science and Technology Key Programs(Z151100004015171),National Natural Science Foundation for Young Scholars(81402519)
摘    要:目的 对比CT引导辅助3D打印模板指导125I粒子植入治疗盆腔复发肿瘤的术前计划与术后验证的剂量学结果,在计划层面探讨该技术的治疗精确性。方法 2015-2016年于我院接受3D打印模板辅助CT引导125I粒子植入的盆腔复发肿瘤患者共12例,植入病灶15个,处方剂量110~150 Gy。设计并制作3D打印模板12块,共15个治疗区。术后验证的剂量学参数与术前计划的比较行配对t检验。结果 术后验证靶区的D90、mPD、V100、V150、V200、CI、EI平均值分别为137.4 Gy、74.4 Gy、90.1%、58.7%、34.4%、0.68、34.2%,术前则分别为140.2 Gy、61.1 Gy、91.8%、64.3%、36.7%、0.69、30.5%(P=0.153、0.024、0.028、0.003、0.302、0.437、0.530)。结论 针对盆腔复发肿瘤,3D打印模板定位、定向准确,术后验证实际剂量分布主要指标均较好达到了术前预计划的设计要求,有良好的治疗精确性。

关 键 词:三维打印  模板  剂量学  肿瘤复发  盆腔/粒子植入  
收稿时间:2016-04-05

Computed tomography image-guided and personalized 3D printed template-assisted 125-iodine seed implantation for recurrent pelvic tumor: a dosimetric study
Jiang Yuliang,Wang Hao,Ji Zhe,Guo Fuxin,Sun Haitao,Fan Jinghong,Zhang Lujing,Tian Suqing,Wang Junjie.Computed tomography image-guided and personalized 3D printed template-assisted 125-iodine seed implantation for recurrent pelvic tumor: a dosimetric study[J].Chinese Journal of Radiation Oncology,2016,25(9):959-964.
Authors:Jiang Yuliang  Wang Hao  Ji Zhe  Guo Fuxin  Sun Haitao  Fan Jinghong  Zhang Lujing  Tian Suqing  Wang Junjie
Institution:Department of Radiation Oncology,Peking Third Hospital,Department of Radiation Oncology,Beijing 100191,China
Abstract:Objective To compare the dosimetric data between preoperative plans and postoperative verification in computed tomography (CT) image-guided and 3D printed template-assisted 125-iodine (125I) seed implantation for recurrent pelvic tumor,and to explore of the accuracy of the technology in treatment planning.Methods A total of 12 patients with recurrent pelvic tumor who received CT image-guided and 3D printed template-assisted 125I seed implantation in our hospital from 2015 to 2016 were enrolled as subjects.125I seeds with a prescribed dose of 110-150 Gy were implanted in 15 lesions.Twelve 3D printed templates were designed and produced for 15 treatment areas.Comparison of the dosimetric parameters between postoperative verification and preoperative plans was made by paired t-test.Results The mean D90,mPD,V100,V150,and V200 were 137.4 Gy,74.4 Gy,90.1%,58.7%,and 34.4%,respectively,in postoperative verification and 140.2 Gy,61.1 Gy,91.8%,64.3%,and 36.7%,respectively,in preoperative plans (P=0.153,0.024,0.028,0.003,and 0.302).The conformity index of gross tumor volume was slightly reduced after operation (0.68 vs.0.69,P=0.437).The external volume index increased after treatment (34.2% vs.30.5%,P=0.530).Conclusions 3D printed template provides accurate positioning and orientation for treating recurrent pelvic tumor.All main indices of the actual dose distribution in postoperative verification meet the expectation of the preoperative plan,indicating satisfactory treatment accuracy.
Keywords:Three-dimensional printing  Template  Dosimetry  Neoplasms recurrence  pelvic/seeds implantation
本文献已被 万方数据 等数据库收录!
点击此处可从《中华放射肿瘤学杂志》浏览原始摘要信息
点击此处可从《中华放射肿瘤学杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号