首页 | 本学科首页   官方微博 | 高级检索  
     

前列腺癌大分割精确放疗分次治疗间和分次治疗内位置变动分析
引用本文:刘跃平,许晶,张连胜,方浩,张彦新,陈冰,戴建荣,李晔雄. 前列腺癌大分割精确放疗分次治疗间和分次治疗内位置变动分析[J]. 中华放射肿瘤学杂志, 2016, 25(11): 1199-1203. DOI: 10.3760/cma.j.issn.1004-4221.2016.11.012
作者姓名:刘跃平  许晶  张连胜  方浩  张彦新  陈冰  戴建荣  李晔雄
作者单位:100021 北京,国家癌症中心/中国医学科学院肿瘤医院放疗科
基金项目:中国癌症基金会北京希望马拉松专项基金( LC2013A01);首都临床特色应用研究( Z131107002213010);国家重大研发计划-以生物组学特征与多模态功能影像为基础的多线束精准放疗方案研究(2016YFC0904600)@@@@sBeijing Marathon of Hope Foundation of Cancer Foundation of China ( LC2013A01);Capital Featured Clinical Application Research Projects ( Z131107002213010);National Key Research and Development Projects of China - A Study of Multibeam Precise Radiotherapy Plans Based on Biological Characteristics and Multimodal Imaging (2016YFC0904600)
摘    要:目的 了解前列腺癌精确大分割放疗时分次间和分次内前列腺靶区位移情况。方法 对 2013—2016年间28例接受5 Gy9次放疗的前列腺癌患者,定位前2周B超引导下经直肠穿刺前列腺内植入纯金标记3颗,仰卧位体膜固定充盈膀胱并直肠内插置直肠扩张球囊充气60 ml后CT定位,Pinnacle系统制定放疗计划。23例患者Synergy加速器治疗,每次疗前CBCT校位,扫描图像与计划图像行骨配准记录摆位误差,然后通过前列腺内金标位置配准记录前列腺位移误差,两次之差为分次间位移。5例患者Novalis加速器治疗,通过前列腺内金标配准,疗中ExacTrac系统实时跟踪金标位置变化,观察前列腺分次内位移。结果 23例患者每次疗前均测量位移共计207次,左右、上下、前后位移平均值分别为(0.05±0.10)、(0.20±0.22)、(0.19±0.18) cm;3个方向>0.3 cm位移分别为1、52、49次,>0.5 cm位移分别为1、29、16次。5例患者每次疗时监测测量金标位置移动5次共计225次,左右、上下、前后位移平均值分别为(0.61±0.50)、(0.68±0.69)、(0.70±0.67) mm,各方向>3 mm移动分别为0、1、1次。结论 前列腺癌精确大分割放疗时分次间位移远远大于分次内位移,分次间位移必须校正后才能放疗。分次内靶区位移尽管变化较小,但仍有必要监测分次内靶区位移,以防患者体位变动造成靶区脱靶照射。直肠内球囊插入对前列腺位置具有固定作用。

关 键 词:前列腺靶区位移   分次间   分次内   前列腺肿瘤/大分割放射疗法基金项目:中国癌症基金会北京希望马拉松专项基金(LC2013A01)  首都临床特色应用研究(Z131107002213010)  国家重大研发计划-以生物组学特征与多模态功能影像为基础的多线束精准放疗方案研究(2016YFC0904600)  
收稿时间:2016-10-13

An analysis of interfractional and intrafractional prostate motion in hypofractionated precise radiotherapy for prostate cancer
Liu Yueping,Xu Jing,Zhang Liansheng,Fang Hao,Zhang Yanxin,Chen Bing,Dai Jianrong,Li Yexiong. An analysis of interfractional and intrafractional prostate motion in hypofractionated precise radiotherapy for prostate cancer[J]. Chinese Journal of Radiation Oncology, 2016, 25(11): 1199-1203. DOI: 10.3760/cma.j.issn.1004-4221.2016.11.012
Authors:Liu Yueping  Xu Jing  Zhang Liansheng  Fang Hao  Zhang Yanxin  Chen Bing  Dai Jianrong  Li Yexiong
Affiliation:Department of Radiation Oncology,National Cancer Center/Cancer Hospital,Chinese Academy of Medical Sciences,Peking Medical College,Beijing 100021,China
Abstract:Objective To investigate the interfractional and intrafractional prostate motion during hypofractionated precise radiotherapy for prostate cancer. Methods From 2013 to 2016,twenty-eight patients who received 5 Gy radiotherapy in 9 fractions for prostate cancer were enrolled as subjects. Every patient had three gold fiducials implanted into the prostate by transrectal ultrasound guidance two weeks before computed tomography (CT) simulation. All patients underwent CT scans in the supine position with full bladders and rectal balloons filled with 60 ml air. The Pinnacle planning system was used to design the treatment plans. Twenty-three patients were treated with a Synergy accelerator. Those patients underwent cone-beam CT (CBCT) scans prior to treatment. The set-up error was recorded by bone alignment between CBCT images and planning CT images. The prostate displacement was then recorded by gold fiducial alignment. The interfraction prostate displacement was defined by the difference between the above two parameters. The other 5 patients were treated with a Novalis accelerator. Based on gold fiducial alignment,the real-time tracking of gold fiducials was carried out by the ExacTrac system to evaluate the intrafractional prostate displacement. Results A total of 207 measurements of interfractional prostate displacement were made in the 23 patients before treatment. The mean interfractional prostate displacements in the left-right (LR),superior-inferior (SI),and anterior-posterior (AP) directions were (0.05±0.10),(0.20±0.22),and (0.19±0.18) cm,respectively. The displacements larger than 0.3 cm in the above three directions were observed in 1,52,and 49 measurements,respectively,while the displacements larger than 0.5 cm in the three directions were observed in 1,29,and 16 measurements,respectively. A total of 225 measurements of gold fiducial displacement were made in the 5 patients during treatment. The mean intrafractional prostate displacements in LR,SI,and AP directions were (0.61±0.50),(0.68±0.69),and (0.70±0.67) mm,respectively. The displacements larger than 3 mm in the three directions were observed in 0,1,and 1 measurement,respectively. Conclusions In hypofractionated precise radiotherapy for prostate cancer,the interfractional prostate displacement is significantly larger than the intrafractional prostate displacement. The interfractional prostate displacement must be corrected before radiotherapy. In order to avoid off-target irradiation due to postural changes in patients,the tracking of the intrafractional prostate displacement is still necessary although the displacement is relatively small. The rectal balloon can help immobilize the prostate.
Keywords:Prostate motion  Interfraction  Intrafraction  Prostate neoplasms/hypofraction-ated radiotherapy
本文献已被 万方数据 等数据库收录!
点击此处可从《中华放射肿瘤学杂志》浏览原始摘要信息
点击此处可从《中华放射肿瘤学杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号