A comparison of reflectance and transmittance near-infrared spectroscopic techniques in determining drug content in intact tablets |
| |
Authors: | Thosar S S Forbess R A Ebube N K Chen Y Rubinovitz R L Kemper M S Reier G E Wheatley T A Shukla A J |
| |
Affiliation: | Department of Pharmaceutical Sciences, College of Pharmacy, University of Tennessee, 26 South Dunlap, 214 Feurt Building, Memphis, TN 38163, USA. ashukla@utmem.edu |
| |
Abstract: | Drug contents of intact tablets were determined using non-destructive near infrared (NIR) reflectance and transmittance spectroscopic techniques. Tablets were compressed from blends of Avicel PH-101 and 0.5% w/w magnesium stearate with varying concentrations of anhydrous theophylline (0, 1, 2, 5, 10, 20 and 40% w/w). Ten tablets from each drug content batch were randomly selected for spectral analysis. Both reflectance and transmittance NIR spectra were obtained from these intact tablets. Actual drug contents of the tablets were then ascertained using a UV-spectrophotometer at 268 nm. Multiple linear regression (MLR) models at 1116 nm and partial least squares (PLS) calibration models were generated from the second derivative spectral data of the tablets in order to predict drug contents of intact tablets. Both the reflectance and the transmittance techniques were able to predict the drug contents in intact tablets over a wide range. However, a comparison of the results of the study indicated that the lowest percent errors of prediction were provided by the PLS calibration models generated from spectral data obtained using the transmittance technique. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|