Magnetocardiographic QT dispersion during cardiovascular autonomic function tests
Authors:Petri Haapalahti  Markku Mäkijärvi  Petri Korhonen  Panu Takala  Juha Montonen  Yrjö Salorinne  Lasse Oikarinen  Matti Viitasalo  Lauri Toivonen
Institution:(1) Laboratory of Biomedical Engineering and the BioMag Laboratory, Helsinki University of Technology, FI;(2) Department of Clinical Physiology and Nuclear Medicine, Helsinki University Central Hospital, FI;(3) Division of Cardiology, Department of Medicine, Helsinki University Central Hospital, Haartmaninkatu 4, 00290 Helsinki, Finland: E-mail: petri.haapalahti@pp.fimnet.fi, FI
Abstract:QT dispersion is considered to reflect nonhomogeneity of ventricular repolarization. The autonomic nervous system modulates QT interval duration, but the effect may not be spatially homogenous. Magnetocardiography (MCG) registers the weak magnetik fields generated by myocardial electric currents with high localizing accuracy. We studied the effect of rapid cardiovascular autonomic nervous adjustment on QT dispersion in MCG. Ten healthy male volunteers were monitored during deep breathing, the Valsalva maneuver, sustained handgrip, hyperventilation, the cold pressor test and mental stress. 67 MCG channels and 12 ECG leads were recorded simultaneously. A computer algorithm was used for QT interval measurements. QT dispersion was defined as maximum – minimum or standard deviation of the QTpeak and QTend intervals. In MCG the QTend dispersion increased during deep inspiration compared with deep expiration (96±19 ms v 73±27 ms, p=0.05). Magnetic QT dispersion tended to increase during the bradycardia phase of the Valsalva maneuver, but the change was obvious only for QTend (55±26 ms v 76±29 ms, p<0.05) Other tests had no significant effect on QT dispersion, not even the cold pressor test, although it causes strong sympathetic activation. Magnetic and electric QTpeak and QTend intervals correlated closely (r=0.93 and 0.91), whereas the QT dispersion measures showed no correlation. In conclusion, magnetic QT dispersion is not modified by rapid changes in autonomic tone, but maneuvers involving deep respiratory efforts and changes in ventricular loading affect QT dispersion measurements. Received: 4 April 2000 Returned for revision: 2 May 2000 Revision received: 20 June 2000 Accepted: 10 July 2000
Keywords:Automatic measurement –  autonomic nervous system –  magnetocardiography –  QT dispersion –  QT interval
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号